Behavior of repaired heat-damaged self-compacted concrete slabs with openings using NSM-CFRP strips

Purpose In this experimental investigation, the behavior of strengthened/repaired heat-damaged one-way self-compacted concrete (SCC) slabs with opening utilizing near-surface-mounted-carbon fiber reinforced polymers (NSM-CFRP) strips was explored. Design/methodology/approach CFRP strip configurations, number of strips and inclination were all investigated in this study. For three hours, slabs were exposed to temperatures of 23°C and 500°C. Four-point load was applied to control slabs, enhanced slabs and repaired slabs. Findings The results indicate that exposing the slabs to high temperatures reduces their load capability. The number of strips and angle of inclination around the slab opening have a considerable impact on the performance of the strengthened and/or repaired slabs, according to the experimental results. The load capacity, toughness and ductility index of a strengthened and/or repaired slab with opening increase as the number of CFRP strips increases by 143.8–150.5%, 137.3–149.9% and 122.3–124.5%, respectively. The use of NSM strips around the opening with zero inclination showed higher load compared to the NSM strips around the opening with other angles. Originality/value It is frequently important to construct openings in the slabs for ventilation, electrical supply, and other purposes. Making openings in slabs might affect the structure’s performance since the concrete and reinforcing would be cut off. SCC is a new type of concrete mixture that can fill in all the voids in the formwork with its own weight without the help of external vibration. As a result, it is necessary to reinforce the slab under flexure and increase the flexural strength of the SCC slab. Therefore, this work investigates the effect of using NSM-CFRP strip on the behavior of one way SCC slabs that have been heat-damaged.

Authors

Institutions

Publication Details

Journal
International Journal of Structural Integrity
Published
2024-08-12
DOI
https://doi.org/10.1108/ijsi-11-2023-0124
Citations
3
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behavior of repaired heat-damaged self-compacted concrete slabs with openings using NSM-CFRP strips

Yasmeen Taleb Obaidat, Ala’ Taleb Obaidat, Ahmed Ashteyat
3 citations
International Journal of Structural Integrity
Structural Behavior of Reinforced Concrete
0.80
article

Behavior of repaired heat-damaged self-compacted concrete slabs with openings using NSM-CFRP strips

Yasmeen Taleb Obaidat, Ala’ Taleb Obaidat, Ahmed Ashteyat
article en
3 citations

Abstract

Purpose In this experimental investigation, the behavior of strengthened/repaired heat-damaged one-way self-compacted concrete (SCC) slabs with opening utilizing near-surface-mounted-carbon fiber reinforced polymers (NSM-CFRP) strips was explored. Design/methodology/approach CFRP strip configurations, number of strips and inclination were all investigated in this study. For three hours, slabs were exposed to temperatures of 23°C and 500°C. Four-point load was applied to control slabs, enhanced slabs and repaired slabs. Findings The results indicate that exposing the slabs to high temperatures reduces their load capability. The number of strips and angle of inclination around the slab opening have a considerable impact on the performance of the strengthened and/or repaired slabs, according to the experimental results. The load capacity, toughness and ductility index of a strengthened and/or repaired slab with opening increase as the number of CFRP strips increases by 143.8–150.5%, 137.3–149.9% and 122.3–124.5%, respectively. The use of NSM strips around the opening with zero inclination showed higher load compared to the NSM strips around the opening with other angles. Originality/value It is frequently important to construct openings in the slabs for ventilation, electrical supply, and other purposes. Making openings in slabs might affect the structure’s performance since the concrete and reinforcing would be cut off. SCC is a new type of concrete mixture that can fill in all the voids in the formwork with its own weight without the help of external vibration. As a result, it is necessary to reinforce the slab under flexure and increase the flexural strength of the SCC slab. Therefore, this work investigates the effect of using NSM-CFRP strip on the behavior of one way SCC slabs that have been heat-damaged.

International Journal of Structural IntegrityVol. 15(5)
University of Jordan (JO), Prince Sattam Bin Abdulaziz University (SA), Philadelphia University (JO), Jordan University of Science and Technology (JO)
Sustainable cities and communities
Openalex Percentile: Top 29%
Structural Behavior of Reinforced Concrete
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.