Effect of liquid level monitor gas injection point size on information source amplitude-frequency characteristics

In order to analyse the effect of the injection point size of the CBM (Coalbed Methane) well level monitor on the amplitude and frequency of pressure pulsations in the wellhead manifold, numerical simulations and experiments were carried out to investigate the effect of different injection point sizes on the amplitude and frequency of pressure pulsations downstream of the sudden expansion structure. Using compressed air as the fluid and the size of the injection point as the variable, the amplitude and frequency of pressure pulsations at different locations downstream of the sudden expansion structure were tested. The results show that the pressure pulsation amplitude is affected by the size of the injection point, and the larger the injection point is, the larger the pressure pulsation amplitude is; the size of the injection point has less influence on the pressure pulsation frequency downstream of the protruding and expanding structure, and the pressure pulsation frequency at 0.5 m and 1 m downstream of the protruding and expanding structure is in the vicinity of 76 Hz. Therefore, the echo signal processing should be filtered around this frequency to obtain accurate liquid level echo signals, so as to improve the accuracy of liquid level monitoring and realise the efficient development of coalbed methane wells.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-08-12
DOI
https://doi.org/10.1038/s41598-024-69779-5
Citations
1
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of liquid level monitor gas injection point size on information source amplitude-frequency characteristics

Pu Liu, Xinyuan Wu, Kaixuan Li, Kailun Quan et al.
1 citations
Scientific Reports
Heat Transfer and Boiling Studies
0.21
article

Effect of liquid level monitor gas injection point size on information source amplitude-frequency characteristics

Pu Liu, Xinyuan Wu, Kaixuan Li, Kailun Quan, Zhongzhi Hu
article en
1 citations

Abstract

In order to analyse the effect of the injection point size of the CBM (Coalbed Methane) well level monitor on the amplitude and frequency of pressure pulsations in the wellhead manifold, numerical simulations and experiments were carried out to investigate the effect of different injection point sizes on the amplitude and frequency of pressure pulsations downstream of the sudden expansion structure. Using compressed air as the fluid and the size of the injection point as the variable, the amplitude and frequency of pressure pulsations at different locations downstream of the sudden expansion structure were tested. The results show that the pressure pulsation amplitude is affected by the size of the injection point, and the larger the injection point is, the larger the pressure pulsation amplitude is; the size of the injection point has less influence on the pressure pulsation frequency downstream of the protruding and expanding structure, and the pressure pulsation frequency at 0.5 m and 1 m downstream of the protruding and expanding structure is in the vicinity of 76 Hz. Therefore, the echo signal processing should be filtered around this frequency to obtain accurate liquid level echo signals, so as to improve the accuracy of liquid level monitoring and realise the efficient development of coalbed methane wells.

Scientific ReportsVol. 14(1)
Sichuan University of Science and Engineering (CN)
Sichuan University of Science and Engineering
Affordable and clean energy
Openalex Percentile: Top 53%
Heat Transfer and Boiling Studies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of liquid level monitor gas injection point size on information source amplitude-frequency characteristics — Pu Liu, Xinyuan Wu, et al. · Scientific Reports (2024) | TGRS Research Map | TGRS