Rated flow coefficient of geometric compensation control valve

Abstract Aiming at the large design error of the rated flow coefficient of existing control valves, it was difficult to meet the requirements of the equipment system. This study adopts the principle of infinite approximation to the existing flow coefficient calculation equation for geometric shape correction compensation, based on which the rated flow coefficient design method was proposed, and simulation and test verification were carried out. The results show that according to the design method, the rated flow coefficient of the control valve can be accurately designed. The variation rule of the simulated value and the test value under the two kinds of spool inner parts is consistent, and the maximum error is not more than 10%, which meets the requirements of industrial standards. The experiment verifies the accuracy and applicability of the design method.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-08-01
DOI
https://doi.org/10.1088/1742-6596/2815/1/012034
Citations
1
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rated flow coefficient of geometric compensation control valve

You Ming, Xiaojie Ye, Shengtao Geng, Hongbin Yu et al.
1 citations
Journal of Physics Conference Series
Hydraulic and Pneumatic Systems
0.21
article

Rated flow coefficient of geometric compensation control valve

You Ming, Xiaojie Ye, Shengtao Geng, Hongbin Yu, Tingting Xu, Yulong Ni, Fengguang Cheng, Zhong Li, Wei Wang
article en
1 citations

Abstract

Abstract Aiming at the large design error of the rated flow coefficient of existing control valves, it was difficult to meet the requirements of the equipment system. This study adopts the principle of infinite approximation to the existing flow coefficient calculation equation for geometric shape correction compensation, based on which the rated flow coefficient design method was proposed, and simulation and test verification were carried out. The results show that according to the design method, the rated flow coefficient of the control valve can be accurately designed. The variation rule of the simulated value and the test value under the two kinds of spool inner parts is consistent, and the maximum error is not more than 10%, which meets the requirements of industrial standards. The experiment verifies the accuracy and applicability of the design method.

Journal of Physics Conference SeriesVol. 2815(1)
Hefei General Machinery Research Institute (China) (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 53%
Hydraulic and Pneumatic Systems
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rated flow coefficient of geometric compensation control valve — You Ming, Xiaojie Ye, et al. · Journal of Physics Conference Series (2024) | TGRS Research Map | TGRS