Common iliac artery aneurysm with narrow inner lumen treated by a novel surgeon-modified inner branch iliac branch device

ObjectivesThe iliac branch device (IBD) has emerged as the optimal method for endovascular reconstruction of internal iliac artery (IIA). However, due to its high anatomical requirements, the applicability rate among East Asians is limited, especially for common iliac artery aneurysm (CIAA) with narrow inner lumen cases. Here, we report a case with narrow distal inner lumen of the CIAA treated with a novel surgeon-modified inner branch iliac branch device (IIBD).MethodsThis is a case report, and consent for publication was obtained from the patient.ResultsThe 1-year follow-up CTA showed that the CIAA regressed without abdominal pain. Right CIA, external iliac artery, and IIA were all patent.ConclusionsThe IIBD technique has lower anatomical requirements for the CIA. Therefore, it may be a feasible option for IIA preservation in cases of CIAA with narrow inner lumen.

Authors

Institutions

Publication Details

Journal
Vascular
Published
2024-08-12
DOI
https://doi.org/10.1177/17085381241273325
Citations
2
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Common iliac artery aneurysm with narrow inner lumen treated by a novel surgeon-modified inner branch iliac branch device

Jiang Xiong, Mingwei Wu, Panpan Yuan
2 citations
Vascular
Aortic aneurysm repair treatments
0.84
article

Common iliac artery aneurysm with narrow inner lumen treated by a novel surgeon-modified inner branch iliac branch device

Jiang Xiong, Mingwei Wu, Panpan Yuan
article en
2 citations

Abstract

ObjectivesThe iliac branch device (IBD) has emerged as the optimal method for endovascular reconstruction of internal iliac artery (IIA). However, due to its high anatomical requirements, the applicability rate among East Asians is limited, especially for common iliac artery aneurysm (CIAA) with narrow inner lumen cases. Here, we report a case with narrow distal inner lumen of the CIAA treated with a novel surgeon-modified inner branch iliac branch device (IIBD).MethodsThis is a case report, and consent for publication was obtained from the patient.ResultsThe 1-year follow-up CTA showed that the CIAA regressed without abdominal pain. Right CIA, external iliac artery, and IIA were all patent.ConclusionsThe IIBD technique has lower anatomical requirements for the CIA. Therefore, it may be a feasible option for IIA preservation in cases of CIAA with narrow inner lumen.

VascularVol. 33(5)
Beijing Institute of Technology (CN), Chinese PLA General Hospital (CN)
National Natural Science Foundation of China, Beijing Science and Technology Planning Project
Openalex Percentile: Top 25%
Aortic aneurysm repair treatments
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Common iliac artery aneurysm with narrow inner lumen treated by a novel surgeon-modified inner branch iliac branch device — Jiang Xiong, Mingwei Wu, et al. · Vascular (2024) | TGRS Research Map | TGRS