Withdrawal Capacity of a Novel Rigging Device for Prefabricated Wood I-Joist Floor Panels

Prefabricated wood construction relies heavily on efficient material handling, yet rigging system design for floor panels remains understudied. This study introduces a novel rigging device that attaches to prefabricated wood I-joist floor panels using self-tapping screws, avoiding potential damage caused by predrilled holes in the sheathing panels and framing members. To establish allowable lifting capacities and optimal installation practices, comprehensive withdrawal tests were conducted on 114-floor panel specimens. Factors influencing withdrawal capacity, such as anchor plate placements, flange materials and width, screw type and quantity, and sheathing panel thickness, were systematically evaluated. Results indicate that withdrawal capacity does not scale linearly with screw quantity and that anchor plates with eight screws centered on the flange enhance performance by up to 20% compared to four-screw configurations. Unexpectedly, thinner sheathing panels yielded higher capacities, potentially due to increased screw penetration depth in the joist flange. In addition, anchor plate orientation, flange width, and flange materials also impact capacity. These findings provide essential data for designing reliable and efficient rigging systems in prefabricated wood construction.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-08-12
DOI
https://doi.org/10.3390/buildings14082484
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Withdrawal Capacity of a Novel Rigging Device for Prefabricated Wood I-Joist Floor Panels

Sigong Zhang, Ying Hei Chui, David Joo
3 links
Buildings
Wood Treatment and Properties
article

Withdrawal Capacity of a Novel Rigging Device for Prefabricated Wood I-Joist Floor Panels

Sigong Zhang, Ying Hei Chui, David Joo
article en

Abstract

Prefabricated wood construction relies heavily on efficient material handling, yet rigging system design for floor panels remains understudied. This study introduces a novel rigging device that attaches to prefabricated wood I-joist floor panels using self-tapping screws, avoiding potential damage caused by predrilled holes in the sheathing panels and framing members. To establish allowable lifting capacities and optimal installation practices, comprehensive withdrawal tests were conducted on 114-floor panel specimens. Factors influencing withdrawal capacity, such as anchor plate placements, flange materials and width, screw type and quantity, and sheathing panel thickness, were systematically evaluated. Results indicate that withdrawal capacity does not scale linearly with screw quantity and that anchor plates with eight screws centered on the flange enhance performance by up to 20% compared to four-screw configurations. Unexpectedly, thinner sheathing panels yielded higher capacities, potentially due to increased screw penetration depth in the joist flange. In addition, anchor plate orientation, flange width, and flange materials also impact capacity. These findings provide essential data for designing reliable and efficient rigging systems in prefabricated wood construction.

BuildingsVol. 14(8)
University of Alberta (CA), Newcastle University (GB)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 87%
Wood Treatment and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.