Influence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials

<b>Objective:</b> The electrically evoked compound action potential (ECAP) is an objective measure to indirectly assess spiral ganglion neurons. The ECAP provides inputs about the prognoses of cochlear implant (CI) recipients. Several factors such as cochlear morphology can affect ECAP measurements. This study aims to investigate the variation effect of cochlear parameters on intraoperative ECAP thresholds. <b>Methods:</b> This is a retrospective study on patients who underwent CI surgery with normal inner ear morphology at our center between 2017 and 2023. Cochlear anatomical parameters, including diameter (A value), width (B value), and height (H value), as well as cochlear duct length (CDL), were measured pre-operatively using OTOPLAN software (Version 3.0). Cochlear implant intraoperative objective measures were also collected. The correlation between the cochlear parameters and intraoperative objective measures was studied. <b>Results:</b> A total of 45 patients underwent cochlear implantation. The mean age was 2.4 ± 0.9 years. The mean CDL and cochlear coverage values were 33.2 ± 2.0 mm and 76.0 ± 5.7%, respectively. The ECAP threshold increased toward basal electrodes, with ECAP values as follows: apical 13.1 ± 3.8; middle 14.3 ± 3.7; and basal 15.6 ± 4.8. Additionally, the A, B, and H values showed a positive correlation with ECAP thresholds in different cochlear regions. The B value showed a significant moderate correlation with ECAP thresholds in the middle and basal electrodes but not in the apical electrodes. <b>Conclusions:</b> Cochlear anatomical parameters correlate with intraoperative ECAP thresholds. The B value showed a significant association with ECAP thresholds in the middle and basal electrodes. These findings could delineate the impact of the B value in CI and optimize electrode selection. Further research is required to study this correlation and its impact on postoperative outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-08-12
DOI
https://doi.org/10.3390/jcm13164716
Citations
1
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.34
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials

Nawaf Fatani, Yassin Abdelsamad, Abdulrahman Alsanosi
1 citations
Journal of Clinical Medicine
Hearing Loss and Rehabilitation
0.34
article

Influence of Cochlear Anatomy on Intraoperative Electrically Evoked Compound Action Potentials

Nawaf Fatani, Yassin Abdelsamad, Abdulrahman Alsanosi
article en
1 citations

Abstract

<b>Objective:</b> The electrically evoked compound action potential (ECAP) is an objective measure to indirectly assess spiral ganglion neurons. The ECAP provides inputs about the prognoses of cochlear implant (CI) recipients. Several factors such as cochlear morphology can affect ECAP measurements. This study aims to investigate the variation effect of cochlear parameters on intraoperative ECAP thresholds. <b>Methods:</b> This is a retrospective study on patients who underwent CI surgery with normal inner ear morphology at our center between 2017 and 2023. Cochlear anatomical parameters, including diameter (A value), width (B value), and height (H value), as well as cochlear duct length (CDL), were measured pre-operatively using OTOPLAN software (Version 3.0). Cochlear implant intraoperative objective measures were also collected. The correlation between the cochlear parameters and intraoperative objective measures was studied. <b>Results:</b> A total of 45 patients underwent cochlear implantation. The mean age was 2.4 ± 0.9 years. The mean CDL and cochlear coverage values were 33.2 ± 2.0 mm and 76.0 ± 5.7%, respectively. The ECAP threshold increased toward basal electrodes, with ECAP values as follows: apical 13.1 ± 3.8; middle 14.3 ± 3.7; and basal 15.6 ± 4.8. Additionally, the A, B, and H values showed a positive correlation with ECAP thresholds in different cochlear regions. The B value showed a significant moderate correlation with ECAP thresholds in the middle and basal electrodes but not in the apical electrodes. <b>Conclusions:</b> Cochlear anatomical parameters correlate with intraoperative ECAP thresholds. The B value showed a significant association with ECAP thresholds in the middle and basal electrodes. These findings could delineate the impact of the B value in CI and optimize electrode selection. Further research is required to study this correlation and its impact on postoperative outcomes.

Journal of Clinical MedicineVol. 13(16)
King Saud University (SA)
Good health and well-being
Openalex Percentile: Top 42%
Hearing Loss and Rehabilitation
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.