Multi-spectral light-field imager for ultra-high temperature measurement

We have developed a multi-spectral light-field (MSLF) imager for high-temperature measurements ranging from 973 K to 2973 K. By integrating an optical-filter-array (OFA) in front of the main lens, the MSLF imager can simultaneously capture both the spatial and spectral information of high-temperature objects. To achieve accurate measurements for ultra-high temperatures, we simulated the effects of wavelength selection on the intensity of MSLF images, so as to determine the optical parameters for different temperature ranges. An in-house MSLF imager was constructed and blackbody tests were conducted to verify the design. In blackbody experiments, 700-850 nm OFA was used for temperatures ranging from 973 K to 1673 K. And for temperature above 1673 K, the 500-650 nm OFA was employed. It is important to note that, except for the OFA, all other optical components remain unchanged. The experimental results indicate that the MSLF imager, equipped with 500-650 nm and 700-850 nm OFAs, can achieve a measurement accuracy better than 0.4% across a broad range of 973-2973 K. Furthermore, a 50% increase in measurement accuracy can be achieved with the proposed wavelength calibration method.

Authors

Publication Details

Journal
Optics Express
Published
2024-08-12
DOI
https://doi.org/10.1364/oe.530621
Citations
5
Primary Topic
Atmospheric aerosols and clouds
Type
article
Field-Weighted Citation Impact
1.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-spectral light-field imager for ultra-high temperature measurement

Shengxian Shi, Fei Zeng, D. Zhang, Hua Fang et al.
5 citations
Optics Express
Atmospheric aerosols and clouds
1.41
article

Multi-spectral light-field imager for ultra-high temperature measurement

Shengxian Shi, Fei Zeng, D. Zhang, Hua Fang, Mingrui Huang, Chunhui Yao
article en
5 citations

Abstract

We have developed a multi-spectral light-field (MSLF) imager for high-temperature measurements ranging from 973 K to 2973 K. By integrating an optical-filter-array (OFA) in front of the main lens, the MSLF imager can simultaneously capture both the spatial and spectral information of high-temperature objects. To achieve accurate measurements for ultra-high temperatures, we simulated the effects of wavelength selection on the intensity of MSLF images, so as to determine the optical parameters for different temperature ranges. An in-house MSLF imager was constructed and blackbody tests were conducted to verify the design. In blackbody experiments, 700-850 nm OFA was used for temperatures ranging from 973 K to 1673 K. And for temperature above 1673 K, the 500-650 nm OFA was employed. It is important to note that, except for the OFA, all other optical components remain unchanged. The experimental results indicate that the MSLF imager, equipped with 500-650 nm and 700-850 nm OFAs, can achieve a measurement accuracy better than 0.4% across a broad range of 973-2973 K. Furthermore, a 50% increase in measurement accuracy can be achieved with the proposed wavelength calibration method.

Optics ExpressVol. 32(18)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Chinese Aeronautical Establishment, National Science and Technology Major Project
Affordable and clean energy
Openalex Percentile: Top 20%
Atmospheric aerosols and clouds
1.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multi-spectral light-field imager for ultra-high temperature measurement — Shengxian Shi, Fei Zeng, et al. · Optics Express (2024) | TGRS Research Map | TGRS