High-Precision Calibration Method and Error Analysis of Infrared Binocular Target Ranging Systems

Infrared binocular cameras, leveraging their distinct thermal imaging capabilities, are well-suited for visual measurement and 3D reconstruction in challenging environments. The precision of camera calibration is essential for leveraging the full potential of these infrared cameras. To overcome the limitations of traditional calibration techniques, a novel method for calibrating infrared binocular cameras is introduced. By creating a virtual target plane that closely mimics the geometry of the real target plane, the method refines the feature point coordinates, leading to enhanced precision in infrared camera calibration. The virtual target plane is obtained by inverse projecting the centers of the imaging ellipses, which are estimated at sub-pixel edge, into three-dimensional space, and then optimized using the RANSAC least squares method. Subsequently, the imaging ellipses are inversely projected onto the virtual target plane, where its centers are identified. The corresponding world coordinates of the feature points are then refined through a linear optimization process. These coordinates are reprojected onto the imaging plane, yielding optimized pixel feature points. The calibration procedure is iteratively performed to determine the ultimate set of calibration parameters. The method has been validated through experiments, demonstrating an average reprojection error of less than 0.02 pixels and a significant 24.5% improvement in calibration accuracy over traditional methods. Furthermore, a comprehensive analysis has been conducted to identify the primary sources of calibration error. Ultimately, this achieves an error rate of less than 5% in infrared stereo ranging within a 55-m range.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2024-08-12
DOI
https://doi.org/10.3390/electronics13163188
Citations
5
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
1.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Precision Calibration Method and Error Analysis of Infrared Binocular Target Ranging Systems

Zuoxiao Dai, Nejie Zhang, Mingjian Gu, Changwen Zeng et al.
5 citations
Electronics
Optical measurement and interference techniques
1.25
article

High-Precision Calibration Method and Error Analysis of Infrared Binocular Target Ranging Systems

Zuoxiao Dai, Nejie Zhang, Mingjian Gu, Changwen Zeng, Rongke Wei
article en
5 citations

Abstract

Infrared binocular cameras, leveraging their distinct thermal imaging capabilities, are well-suited for visual measurement and 3D reconstruction in challenging environments. The precision of camera calibration is essential for leveraging the full potential of these infrared cameras. To overcome the limitations of traditional calibration techniques, a novel method for calibrating infrared binocular cameras is introduced. By creating a virtual target plane that closely mimics the geometry of the real target plane, the method refines the feature point coordinates, leading to enhanced precision in infrared camera calibration. The virtual target plane is obtained by inverse projecting the centers of the imaging ellipses, which are estimated at sub-pixel edge, into three-dimensional space, and then optimized using the RANSAC least squares method. Subsequently, the imaging ellipses are inversely projected onto the virtual target plane, where its centers are identified. The corresponding world coordinates of the feature points are then refined through a linear optimization process. These coordinates are reprojected onto the imaging plane, yielding optimized pixel feature points. The calibration procedure is iteratively performed to determine the ultimate set of calibration parameters. The method has been validated through experiments, demonstrating an average reprojection error of less than 0.02 pixels and a significant 24.5% improvement in calibration accuracy over traditional methods. Furthermore, a comprehensive analysis has been conducted to identify the primary sources of calibration error. Ultimately, this achieves an error rate of less than 5% in infrared stereo ranging within a 55-m range.

ElectronicsVol. 13(16)
Chinese Academy of Sciences (CN), Shanghai Institute of Technical Physics (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 19%
Optical measurement and interference techniques
1.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.