Validation of an mHealth System for Monitoring Fundamental Physiological Parameters in the Clinical Setting

The aim of this work was to validate the measurements of three physiological parameters, namely, body temperature, heart rate, and peripheral oxygen saturation, captured with an out-of-the-lab device using measurements taken with clinically proven devices. The out-of-the-lab specialized device was integrated into a customized mHealth application, e-CoVig, developed within the AIM Health project. To perform the analysis, single consecutive measurements of the three vital parameters obtained with e-CoVig and with the standard devices from patients in an intensive care unit were collected, preprocessed, and then analyzed through classical agreement analysis, where we used Lin's concordance coefficient to assess the agreement correlation and Bland-Altman plots with exact confidence intervals for the limits of agreement to analyze the paired data readings. The existence of possible systematic errors was also addressed, where we found the presence of additive errors, which were corrected, and weak proportional biases. We obtained the mean overall agreement between the measurements taken with the novel e-CoVig device and the reference devices for the measured quantities. Although some limitations in this study were encountered, we present more advanced methods for their further assessment.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-10
DOI
https://doi.org/10.3390/s24165164
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of an mHealth System for Monitoring Fundamental Physiological Parameters in the Clinical Setting

Elsa C. FRAGOSO, Luís Brás Rosário, Hugo Silva, Miguel Sales Dias et al.
12 links
Sensors
Hemodynamic Monitoring and Therapy
article

Validation of an mHealth System for Monitoring Fundamental Physiological Parameters in the Clinical Setting

Elsa C. FRAGOSO, Luís Brás Rosário, Hugo Silva, Miguel Sales Dias, Filipe Martins
article en

Abstract

The aim of this work was to validate the measurements of three physiological parameters, namely, body temperature, heart rate, and peripheral oxygen saturation, captured with an out-of-the-lab device using measurements taken with clinically proven devices. The out-of-the-lab specialized device was integrated into a customized mHealth application, e-CoVig, developed within the AIM Health project. To perform the analysis, single consecutive measurements of the three vital parameters obtained with e-CoVig and with the standard devices from patients in an intensive care unit were collected, preprocessed, and then analyzed through classical agreement analysis, where we used Lin's concordance coefficient to assess the agreement correlation and Bland-Altman plots with exact confidence intervals for the limits of agreement to analyze the paired data readings. The existence of possible systematic errors was also addressed, where we found the presence of additive errors, which were corrected, and weak proportional biases. We obtained the mean overall agreement between the measurements taken with the novel e-CoVig device and the reference devices for the measured quantities. Although some limitations in this study were encountered, we present more advanced methods for their further assessment.

SensorsVol. 24(16)
Iscte – Instituto Universitário de Lisboa (PT), University of Lisbon (PT), Instituto de Telecomunicações (PT), Hospital de Santa Maria (PT), Instituto Superior Técnico (PT)
Fundação para a Ciência e a Tecnologia
Quality Education
Openalex Percentile: Top 76%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Validation of an mHealth System for Monitoring Fundamental Physiological Parameters in the Clinical Setting — Elsa C. FRAGOSO, Luís Brás Rosário, et al. · Sensors (2024) | TGRS Research Map | TGRS