Impact of balcony geometry on the performance of rubberized concrete structures against progressive collapse

Purpose Evaluate the performance of progressive collapse of full-scale three-dimensional structure (3D) beam-slab substructures with and without the presence of reinforced concrete (RC) balconies using two concrete mixes [normal concrete (NC) and rubberized concrete (RuC)]. Design/methodology/approach This study examines two concrete mixes to evaluate the progressive collapse performance of full-scale 3D beam-slab substructures with and without the presence of RC balconies using the finite element (FE) method. Findings The results showed that the vertical loads that affect the structures of the specimens after including the balconies in the modeling increased by an average of 29.3% compared with those of the specimens without balconies. The specimens with balconies exhibited higher resistance to progressive collapse in comparison with the specimens without balconies. Moreover, the RuC specimens performed very efficiently during the catenary stage, which significantly enhanced robustness to substantial deformation to delay or mitigate the progressive collapse risk. Originality/value All the experimental and numerical studies of the RC beam-slab substructures under progressive collapse scenarios are limited and do not consider the balcony’s presence in the building. Although balconies represent a common feature of multistory residential buildings, their presence in the building has more likely caused the failure of this building compared with a building without balconies. However, balconies are an external extension of RC slabs, which can provide extra resistance through tensile membrane action (TMA) or compressive membrane action (CMA). All those gaps have not been investigated yet.

Authors

Institutions

Publication Details

Journal
Multidiscipline Modeling in Materials and Structures
Published
2024-08-12
DOI
https://doi.org/10.1108/mmms-02-2024-0048
Citations
3
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of balcony geometry on the performance of rubberized concrete structures against progressive collapse

Aref A. Abadel, Ahmed Hamoda, Moncef L. Nehdi, Ibrahim M.H. Alshaikh
3 citations
Multidiscipline Modeling in Materials and Structures
Structural Response to Dynamic Loads
0.78
article

Impact of balcony geometry on the performance of rubberized concrete structures against progressive collapse

Aref A. Abadel, Ahmed Hamoda, Moncef L. Nehdi, Ibrahim M.H. Alshaikh
article en
3 citations

Abstract

Purpose Evaluate the performance of progressive collapse of full-scale three-dimensional structure (3D) beam-slab substructures with and without the presence of reinforced concrete (RC) balconies using two concrete mixes [normal concrete (NC) and rubberized concrete (RuC)]. Design/methodology/approach This study examines two concrete mixes to evaluate the progressive collapse performance of full-scale 3D beam-slab substructures with and without the presence of RC balconies using the finite element (FE) method. Findings The results showed that the vertical loads that affect the structures of the specimens after including the balconies in the modeling increased by an average of 29.3% compared with those of the specimens without balconies. The specimens with balconies exhibited higher resistance to progressive collapse in comparison with the specimens without balconies. Moreover, the RuC specimens performed very efficiently during the catenary stage, which significantly enhanced robustness to substantial deformation to delay or mitigate the progressive collapse risk. Originality/value All the experimental and numerical studies of the RC beam-slab substructures under progressive collapse scenarios are limited and do not consider the balcony’s presence in the building. Although balconies represent a common feature of multistory residential buildings, their presence in the building has more likely caused the failure of this building compared with a building without balconies. However, balconies are an external extension of RC slabs, which can provide extra resistance through tensile membrane action (TMA) or compressive membrane action (CMA). All those gaps have not been investigated yet.

Multidiscipline Modeling in Materials and StructuresVol. 20(5)
Kafrelsheikh University (EG), Universiti Sains Malaysia (MY), Hamilton College (US), King Saud University (SA), Hospital Universiti Sains Malaysia (MY), Riyadh Elm University (SA), Hamilton Medical (Switzerland) (CH), Hamilton Health Sciences (CA), McMaster University (CA)
Sustainable cities and communities
Openalex Percentile: Top 31%
Structural Response to Dynamic Loads
0.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.