Axial clearance measurement method based on time-frequency analysis for high-speed targets in narrow spaces

Frequency-scanning interferometry (FSI) is a high-precision distance measurement method. When applied to high-speed moving targets in narrow spaces, the initial short distance combined with significant Doppler effects due to motion can cause the FSI signal to exhibit negative frequency components. Because frequency identification methods only recognize positive frequencies, phase extraction is limited to phase increments, which in turn leads to errors in the initial clearance value derived from the slope demodulation of the phase increment. An axial clearance demodulation algorithm is proposed for FSI signals, based on negative frequency identification and phase correction. By extracting time-frequency signals, using a bidirectional threshold to determine the zero-crossing point of the frequency, and constructing a sign judgment square wave function, the method corrects the frequency interval and the relative phase variation, thereby overcoming the inherent limitations of FSI that require a large initial clearance and low rotational speed. Experimental results demonstrate that at a rotational speed of 12,000 rpm, the corrected average clearance relative to the static average clearance reduces the error from 36.5% to 0.4%.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2024-08-12
DOI
https://doi.org/10.1364/oe.534161
Citations
1
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial clearance measurement method based on time-frequency analysis for high-speed targets in narrow spaces

Bin Shao, Xiaohua Lei, Peng Zhang, Xianming Liu et al.
1 citations
Optics Express
Advanced Measurement and Metrology Techniques
0.21
article

Axial clearance measurement method based on time-frequency analysis for high-speed targets in narrow spaces

Bin Shao, Xiaohua Lei, Peng Zhang, Xianming Liu, Yilin Ren
article en
1 citations

Abstract

Frequency-scanning interferometry (FSI) is a high-precision distance measurement method. When applied to high-speed moving targets in narrow spaces, the initial short distance combined with significant Doppler effects due to motion can cause the FSI signal to exhibit negative frequency components. Because frequency identification methods only recognize positive frequencies, phase extraction is limited to phase increments, which in turn leads to errors in the initial clearance value derived from the slope demodulation of the phase increment. An axial clearance demodulation algorithm is proposed for FSI signals, based on negative frequency identification and phase correction. By extracting time-frequency signals, using a bidirectional threshold to determine the zero-crossing point of the frequency, and constructing a sign judgment square wave function, the method corrects the frequency interval and the relative phase variation, thereby overcoming the inherent limitations of FSI that require a large initial clearance and low rotational speed. Experimental results demonstrate that at a rotational speed of 12,000 rpm, the corrected average clearance relative to the static average clearance reduces the error from 36.5% to 0.4%.

Optics ExpressVol. 32(18)
China Academy of Space Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 53%
Advanced Measurement and Metrology Techniques
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.