Structural performance analysis of a new bolt–steel plate connection precast concrete sandwich wall structure

This study proposed a new low-rise bolt–steel plate connection precast concrete sandwich wall structure (PCSWS). Shake table testing was conducted on an experimental model of the bolt–steel plate connection PCSWS with two stories. The experimental phenomenon, failure pattern, displacement response, dynamic characteristics, and global hysteresis were analyzed in detail. The test results revealed that the proposed structure demonstrated excellent seismic performance without any structural cracks when subjected to an excitation intensity level of IX for Model-1. The seismic damage was moderate with no significant structural cracks after an excitation intensity level of IX for Model-2. Cracks in Model-2 occurred in the sequence of the places at the bottoms of the columns, the door corners, window opening corners, and the filled surfaces in the bolt–steel plate connection joint zone on the first floor. The observed damage states were primarily light and moderate, indicating the structure’s ability to withstand seismic events.

Authors

Institutions

Publication Details

Journal
Canadian Journal of Civil Engineering
Published
2024-08-12
DOI
https://doi.org/10.1139/cjce-2023-0291
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural performance analysis of a new bolt–steel plate connection precast concrete sandwich wall structure

Hongxing Xiong, Jiang Chen, Yang Lu, Feng Xiong et al.
Canadian Journal of Civil Engineering
Structural Load-Bearing Analysis
article

Structural performance analysis of a new bolt–steel plate connection precast concrete sandwich wall structure

Hongxing Xiong, Jiang Chen, Yang Lu, Feng Xiong, Wen Chen, Wenrui Li, Qi Ge
article en

Abstract

This study proposed a new low-rise bolt–steel plate connection precast concrete sandwich wall structure (PCSWS). Shake table testing was conducted on an experimental model of the bolt–steel plate connection PCSWS with two stories. The experimental phenomenon, failure pattern, displacement response, dynamic characteristics, and global hysteresis were analyzed in detail. The test results revealed that the proposed structure demonstrated excellent seismic performance without any structural cracks when subjected to an excitation intensity level of IX for Model-1. The seismic damage was moderate with no significant structural cracks after an excitation intensity level of IX for Model-2. Cracks in Model-2 occurred in the sequence of the places at the bottoms of the columns, the door corners, window opening corners, and the filled surfaces in the bolt–steel plate connection joint zone on the first floor. The observed damage states were primarily light and moderate, indicating the structure’s ability to withstand seismic events.

Canadian Journal of Civil EngineeringVol. 52(1)
Southwest University of Science and Technology (CN), Sichuan University (CN), China State Construction Engineering (China) (CN)
Sustainable cities and communities
Openalex Percentile: Top 85%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Structural performance analysis of a new bolt–steel plate connection precast concrete sandwich wall structure — Hongxing Xiong, Jiang Chen, et al. · Canadian Journal of Civil Engineering (2024) | TGRS Research Map | TGRS