Determining the Position of Gamma-Ray Interaction Using Large Scintillation Detectors and the Least Number of Photomultiplier Tubes

Determining the position of interaction is of great interest for gamma-ray imaging in various nuclear applications. Among all gamma-ray detectors, scintillation detectors are commonly exploited for imaging purposes because they can be prepared in large dimensions and are economically affordable. In this work, the general shape of the measured gamma-ray spectra of two long and large-area plastic scintillation detectors are analyzed by artificial neural networks to determine the position of interaction in one and two dimensions (1D and 2D), respectively. The position of interaction was treated as the position of a 137Cs gamma-ray point source on the long and large-area scintillation detectors. Utilizing this method, only one photomultiplier tube (PMT) was used for 1D positioning of interaction in a 4 × 4 × 35-cm3 long plastic detector, while just two PMTs were applied for 2D positioning of interaction in a 50 × 50 × 5-cm3 large-area plastic detector. The position of interaction in the long detector was determined with a resolution of 1 cm and a mean absolute error of less than 1%, while a resolution of 5 cm with a mean absolute error of 13% was achieved for the large-area detector.

Authors

Institutions

Publication Details

Journal
Nuclear Technology
Published
2024-08-12
DOI
https://doi.org/10.1080/00295450.2024.2385796
Citations
1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining the Position of Gamma-Ray Interaction Using Large Scintillation Detectors and the Least Number of Photomultiplier Tubes

Hadi Shahabinejad
1 citations
Nuclear Technology
Radiation Detection and Scintillator Technologies
0.61
article

Determining the Position of Gamma-Ray Interaction Using Large Scintillation Detectors and the Least Number of Photomultiplier Tubes

Hadi Shahabinejad
article en
1 citations

Abstract

Determining the position of interaction is of great interest for gamma-ray imaging in various nuclear applications. Among all gamma-ray detectors, scintillation detectors are commonly exploited for imaging purposes because they can be prepared in large dimensions and are economically affordable. In this work, the general shape of the measured gamma-ray spectra of two long and large-area plastic scintillation detectors are analyzed by artificial neural networks to determine the position of interaction in one and two dimensions (1D and 2D), respectively. The position of interaction was treated as the position of a 137Cs gamma-ray point source on the long and large-area scintillation detectors. Utilizing this method, only one photomultiplier tube (PMT) was used for 1D positioning of interaction in a 4 × 4 × 35-cm3 long plastic detector, while just two PMTs were applied for 2D positioning of interaction in a 50 × 50 × 5-cm3 large-area plastic detector. The position of interaction in the long detector was determined with a resolution of 1 cm and a mean absolute error of less than 1%, while a resolution of 5 cm with a mean absolute error of 13% was achieved for the large-area detector.

Nuclear TechnologyVol. 211(6)
Ruđer Bošković Institute (HR)
Openalex Percentile: Top 33%
Radiation Detection and Scintillator Technologies
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.