Thickness Measurement and Sensitivity of Copper/Nickel Electroplating Results of Electrolyte Solution Temperature Variation

Currently, cryogenic thermometers are needed and one of the uses of cryogenic thermometers is to measure the temperature of food preservation flasks. Research has been conducted on the manufacture of cryogenic thermometers derived from Cu/Ni coils by electroplating process with temperature variation treatment of electrolyte solution. The purpose of this study is to determine the effect of electrolyte solution temperature variation treatment on Ni thickness and Cu/Ni sensitivity as a low-temperature sensor. Electroplating was carried out with electrolyte temperature parameters of 30˚C-70˚C, electrode distance of 4 cm, voltage of 4.5 volts, and coating time of 4 minutes. The electrolyte solution was a mixture of NiSO4 260 g, NiCl2 60 g, H3BO3 40 g, and Aquades 1000 mL. Based on the results of the study, a remarkable condition was obtained on the thickness of Ni; namely, at 40 ˚C, the thickness increased to 1.08 mm. In addition, the best temperature can produce the greatest sensitivity value in Cu/Ni coil electroplating, namely at 50 ˚C.

Authors

Institutions

Publication Details

Journal
SPEKTRA Jurnal Fisika dan Aplikasinya
Published
2024-08-12
DOI
https://doi.org/10.21009/spektra.092.01
Primary Topic
Induction Heating and Inverter Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thickness Measurement and Sensitivity of Copper/Nickel Electroplating Results of Electrolyte Solution Temperature Variation

Moh. Toifur, Okimustava Okimustava, Rizka Nuzul Islamiyati
SPEKTRA Jurnal Fisika dan Aplikasinya
Induction Heating and Inverter Technology
article

Thickness Measurement and Sensitivity of Copper/Nickel Electroplating Results of Electrolyte Solution Temperature Variation

Moh. Toifur, Okimustava Okimustava, Rizka Nuzul Islamiyati
article en

Abstract

Currently, cryogenic thermometers are needed and one of the uses of cryogenic thermometers is to measure the temperature of food preservation flasks. Research has been conducted on the manufacture of cryogenic thermometers derived from Cu/Ni coils by electroplating process with temperature variation treatment of electrolyte solution. The purpose of this study is to determine the effect of electrolyte solution temperature variation treatment on Ni thickness and Cu/Ni sensitivity as a low-temperature sensor. Electroplating was carried out with electrolyte temperature parameters of 30˚C-70˚C, electrode distance of 4 cm, voltage of 4.5 volts, and coating time of 4 minutes. The electrolyte solution was a mixture of NiSO4 260 g, NiCl2 60 g, H3BO3 40 g, and Aquades 1000 mL. Based on the results of the study, a remarkable condition was obtained on the thickness of Ni; namely, at 40 ˚C, the thickness increased to 1.08 mm. In addition, the best temperature can produce the greatest sensitivity value in Cu/Ni coil electroplating, namely at 50 ˚C.

SPEKTRA Jurnal Fisika dan AplikasinyaVol. 9(2)
Universitas Ahmad Dahlan (ID)
Zero hunger
Openalex Percentile: Top 88%
Induction Heating and Inverter Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.