ANALYSIS OF THERMAL TRANSFER VALUES IN TEACHING CLASSROOMS

Erratic weather, such as intense heat followed by heavy rain, is causing air pollution in the sky of Jakarta. According to the SNI 03-6389-2011, which deals with energy conservation in building envelopes, the overall thermal transfer value (OTTV) for walls should not exceed 35 W/m2. This study aims to analyze OTTV in Class T and Class S. Class S uses clear glass, while Class T has a shading device in the form of a sunglass sticker. The method used involves calculating the total outer wall area, glass area, window-to-wall ratio (WWR), solar factor value, and then obtaining the OTTV. The results of the study show that the WWR value for Class T was 0.5, while for Class S it was 0.4. The OTTV value in Class T is 58.74 W/m2, whereas the OTTV in Class S is 70.64 W/m2. Despite both classrooms not meeting the SNI requirements, the classrooms using shading devices have OTTV values closer to the SNI standard.

Authors

Institutions

Publication Details

Journal
AL ULUM JURNAL SAINS DAN TEKNOLOGI
Published
2024-08-12
DOI
https://doi.org/10.31602/jst.v10i2.15679
Citations
1
Primary Topic
Experimental Learning in Engineering
Type
article
Field-Weighted Citation Impact
0.32
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ANALYSIS OF THERMAL TRANSFER VALUES IN TEACHING CLASSROOMS

Denny Yatmadi, Dyah Nurwidyaningrum, Tri Wulan Sari, Sujito Sujito et al.
1 citations
AL ULUM JURNAL SAINS DAN TEKNOLOGI
Experimental Learning in Engineering
0.32
article

ANALYSIS OF THERMAL TRANSFER VALUES IN TEACHING CLASSROOMS

Denny Yatmadi, Dyah Nurwidyaningrum, Tri Wulan Sari, Sujito Sujito, Jonathan Saputra
article en
1 citations

Abstract

Erratic weather, such as intense heat followed by heavy rain, is causing air pollution in the sky of Jakarta. According to the SNI 03-6389-2011, which deals with energy conservation in building envelopes, the overall thermal transfer value (OTTV) for walls should not exceed 35 W/m2. This study aims to analyze OTTV in Class T and Class S. Class S uses clear glass, while Class T has a shading device in the form of a sunglass sticker. The method used involves calculating the total outer wall area, glass area, window-to-wall ratio (WWR), solar factor value, and then obtaining the OTTV. The results of the study show that the WWR value for Class T was 0.5, while for Class S it was 0.4. The OTTV value in Class T is 58.74 W/m2, whereas the OTTV in Class S is 70.64 W/m2. Despite both classrooms not meeting the SNI requirements, the classrooms using shading devices have OTTV values closer to the SNI standard.

AL ULUM JURNAL SAINS DAN TEKNOLOGIVol. 10(2)
State University of Malang (ID), Jakarta State Polytechnic (ID)
Affordable and clean energy
Openalex Percentile: Top 39%
Experimental Learning in Engineering
0.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ANALYSIS OF THERMAL TRANSFER VALUES IN TEACHING CLASSROOMS — Denny Yatmadi, Dyah Nurwidyaningrum, et al. · AL ULUM JURNAL SAINS DAN TEKNOLOGI (2024) | TGRS Research Map | TGRS