Real-time Direct Temperature Estimation of MEMS Resonators Through Indirect Q-factor Measurement

Extensive research have been conducted to improve the characteristics of resonant frequency with temperature variations in silicon resonators for various applications. However, temperature measurement delays due to temperature gradient across the chip make it challenging to improve temperature characteristics. This study proposes, a method of measuring the Q-factor of MEMS resonators in real time and estimating their temperature without any time delays using the measured Q-factor. The proposed real-time indirect Q-factor estimation method was validated based on ring-down Q-factor measurement method, and it is suitability for application in the operating environment of MEMS resonant accelerometers was assessed through acceleration-induced testing and temperature cycling tests. The experimental results on the variation of the resonant frequency with temperature validate an improvement in temperature estimation using the proposed method. The proposed method reduced temperature hysteresis characteristics from 3.2019Hz to 1.122Hz, achieving a 65% improvement.

Authors

Publication Details

Journal
Journal of Institute of Control Robotics and Systems
Published
2024-08-11
DOI
https://doi.org/10.5302/j.icros.2024.24.0066
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time Direct Temperature Estimation of MEMS Resonators Through Indirect Q-factor Measurement

Hyoung-Kyoon Jung, H C Kim, Woo-Hyeop Jang
Journal of Institute of Control Robotics and Systems
Advanced MEMS and NEMS Technologies
article

Real-time Direct Temperature Estimation of MEMS Resonators Through Indirect Q-factor Measurement

Hyoung-Kyoon Jung, H C Kim, Woo-Hyeop Jang
article en

Abstract

Extensive research have been conducted to improve the characteristics of resonant frequency with temperature variations in silicon resonators for various applications. However, temperature measurement delays due to temperature gradient across the chip make it challenging to improve temperature characteristics. This study proposes, a method of measuring the Q-factor of MEMS resonators in real time and estimating their temperature without any time delays using the measured Q-factor. The proposed real-time indirect Q-factor estimation method was validated based on ring-down Q-factor measurement method, and it is suitability for application in the operating environment of MEMS resonant accelerometers was assessed through acceleration-induced testing and temperature cycling tests. The experimental results on the variation of the resonant frequency with temperature validate an improvement in temperature estimation using the proposed method. The proposed method reduced temperature hysteresis characteristics from 3.2019Hz to 1.122Hz, achieving a 65% improvement.

Journal of Institute of Control Robotics and SystemsVol. 30(8)
Affordable and clean energy
Openalex Percentile: Top 90%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-time Direct Temperature Estimation of MEMS Resonators Through Indirect Q-factor Measurement — Hyoung-Kyoon Jung, H C Kim, et al. · Journal of Institute of Control Robotics and Systems (2024) | TGRS Research Map | TGRS