Accidental Journeys: Intrauterine Contraceptive Device Migration to the Sigmoid Colon and Right Ovary – A Report of Two Cases

Ectopic migration of intrauterine contraceptive devices (IUCDs) to neighboring organs is infrequent, but can lead to severe consequences. This article presents two cases of IUCD migration resulting in serious outcomes, including sigmoid colon penetration in the first case (a 25-year-old) and right ovary penetration and contraceptive failure leading to pregnancy in the second case (a 19-yearold). The IUCD was inserted 6 months ago and 2 years ago in the first and second cases, respectively. Both cases underwent surgical exploration and IUCD removal. Fortunately, both patients experienced uneventful recoveries without any complications. In conclusion, although uncommon, IUCD ectopic migration may result in contraceptive failure and, in some cases, organ perforation. Thorough evaluation during care visits is necessary for proper IUCD placement, and radiological assessment should be performed in cases of a ‘missed IUCD,’ even if the patient is asymptomatic. Timely removal of an ectopic IUCD is strongly advised to minimize potential risks.

Authors

Institutions

Publication Details

Journal
Case Reports in Clinical Practice
Published
2024-08-11
DOI
https://doi.org/10.18502/crcp.v8i6.16235
Primary Topic
Reproductive Health and Contraception
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accidental Journeys: Intrauterine Contraceptive Device Migration to the Sigmoid Colon and Right Ovary – A Report of Two Cases

Qasem Alyhari, Saleh Al‐wageeh, Abdulfattah Altam, Faisal Ahmed
Case Reports in Clinical Practice
Reproductive Health and Contraception
article

Accidental Journeys: Intrauterine Contraceptive Device Migration to the Sigmoid Colon and Right Ovary – A Report of Two Cases

Qasem Alyhari, Saleh Al‐wageeh, Abdulfattah Altam, Faisal Ahmed
article en

Abstract

Ectopic migration of intrauterine contraceptive devices (IUCDs) to neighboring organs is infrequent, but can lead to severe consequences. This article presents two cases of IUCD migration resulting in serious outcomes, including sigmoid colon penetration in the first case (a 25-year-old) and right ovary penetration and contraceptive failure leading to pregnancy in the second case (a 19-yearold). The IUCD was inserted 6 months ago and 2 years ago in the first and second cases, respectively. Both cases underwent surgical exploration and IUCD removal. Fortunately, both patients experienced uneventful recoveries without any complications. In conclusion, although uncommon, IUCD ectopic migration may result in contraceptive failure and, in some cases, organ perforation. Thorough evaluation during care visits is necessary for proper IUCD placement, and radiological assessment should be performed in cases of a ‘missed IUCD,’ even if the patient is asymptomatic. Timely removal of an ectopic IUCD is strongly advised to minimize potential risks.

Case Reports in Clinical Practice
Sana'a University (YE), Ibb University (YE)
Good health and well-being
Openalex Percentile: Top 80%
Reproductive Health and Contraception
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.