PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT

Objectives: This study aims to demonstrate reduced iodine contrast media (CM) in routine abdominal CT scans in portal venous phase (PVP) using a photon-counting detector CT (PCD-CT) compared to total body weight (TBW) and kV-adapted CM injection protocols on a state-of-the-art energy-integrating detector CT (EID-CT) while maintaining sufficient image quality (IQ). Materials and Methods: Consecutive contrast-enhanced abdominal PVP CT scans from an EID-CT (Nov 2022-March 2024) and a PCD-CT (Sep 2023-Dec 2023) were compared. CM parameters (total iodine load (TIL), iodine delivery rate (IDR) and dosing factor (DF)) were reported. An individualized acquisition and CM injection protocol based on TBW and kV was applied for the EID-CT and a TBW adapted CM injection protocol was used for the PCD-CT. Objective IQ was evaluated with mean attenuation (Hounsfield Units, HU), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)). Subjective IQ was assessed via a 5-point Likert scale by 2 expert readers based on diagnostic confidence. Results: Based on 91 EID-CT scans and 102 PCD-CT scans a TIL reduction of 20.1 % was observed for PCD-CT. PCD-CT demonstrated significantly higher SNR (9.9 ± 1.7 vs. 9.1 ± 1.8, p < 0.001) and CNR (5.1 ± 1.7 vs. 4.3 ± 1.3, p < 0.001) compared to EID-CT. Subjective IQ assessment showed that all scans had sufficient diagnostic IQ. Conclusions: PCD-CT allows for CM reduction while providing higher SNR and CNR compared to EID-CT, using clinical individualized scan and CM injection protocols.

Authors

Institutions

Publication Details

Journal
European Journal of Radiology
Published
2024-08-10
DOI
https://doi.org/10.1016/j.ejrad.2024.111680
Citations
10
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
1.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT

Nienke G. Eijsvoogel, Cécile R. L. P. N. Jeukens, Bibi Martens, Joachim Ernst Wildberger et al.
10 citations
European Journal of Radiology
Advanced X-ray and CT Imaging
1.84
article

PCD-CT enables contrast media reduction in abdominal imaging compared to an individualized kV-adapted contrast media injection protocol on EID-CT

Nienke G. Eijsvoogel, Cécile R. L. P. N. Jeukens, Bibi Martens, Joachim Ernst Wildberger, Thomas G. Flohr, Eva J I Hoeijmakers, Lion Stammen, Johanna M Hersbach, Joey C J G Pernot
article en
10 citations

Abstract

Objectives: This study aims to demonstrate reduced iodine contrast media (CM) in routine abdominal CT scans in portal venous phase (PVP) using a photon-counting detector CT (PCD-CT) compared to total body weight (TBW) and kV-adapted CM injection protocols on a state-of-the-art energy-integrating detector CT (EID-CT) while maintaining sufficient image quality (IQ). Materials and Methods: Consecutive contrast-enhanced abdominal PVP CT scans from an EID-CT (Nov 2022-March 2024) and a PCD-CT (Sep 2023-Dec 2023) were compared. CM parameters (total iodine load (TIL), iodine delivery rate (IDR) and dosing factor (DF)) were reported. An individualized acquisition and CM injection protocol based on TBW and kV was applied for the EID-CT and a TBW adapted CM injection protocol was used for the PCD-CT. Objective IQ was evaluated with mean attenuation (Hounsfield Units, HU), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)). Subjective IQ was assessed via a 5-point Likert scale by 2 expert readers based on diagnostic confidence. Results: Based on 91 EID-CT scans and 102 PCD-CT scans a TIL reduction of 20.1 % was observed for PCD-CT. PCD-CT demonstrated significantly higher SNR (9.9 ± 1.7 vs. 9.1 ± 1.8, p < 0.001) and CNR (5.1 ± 1.7 vs. 4.3 ± 1.3, p < 0.001) compared to EID-CT. Subjective IQ assessment showed that all scans had sufficient diagnostic IQ. Conclusions: PCD-CT allows for CM reduction while providing higher SNR and CNR compared to EID-CT, using clinical individualized scan and CM injection protocols.

European Journal of RadiologyVol. 179
Maastricht University Medical Centre (NL), Maastricht University (NL)
Openalex Percentile: Top 15%
Advanced X-ray and CT Imaging
1.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.