Impact of inductive and resistive fault current limiters for transient stability Improvement based on difference between accelerating and decelerating areas

The utilization of fault current limiters (FCLs) provides an effective approach to alleviate the negative consequences associated with short circuit currents. This equipment can affect other system specifications. In this paper, the effects of FCL on power system transient stability are investigated by a theoretical-comparative study. In this study, different FCL impedances (inductive and resistive) are analyzed and compared considering two locations for FCL installation and different locations of fault occurrence in a single-machine infinite bus system. To evaluate the power system's transient stability, the authors adopt an approach based on the equal area criterion, which calculates the difference between accelerating and decelerating areas. Another issue addressed in this article is the fault-clearing time effect on the power system's transient stability as FCL is installed in the power grid. The results have been confirmed through the use of MATLAB software.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-08-01
DOI
https://doi.org/10.1016/j.heliyon.2024.e35619
Citations
2
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.42
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of inductive and resistive fault current limiters for transient stability Improvement based on difference between accelerating and decelerating areas

Tahere Daemi, Mahdi Dehghani-Ashkezari, Hamidreza Akbari, Mahmoud Modaresi et al.
2 citations
Heliyon
HVDC Systems and Fault Protection
0.42
article

Impact of inductive and resistive fault current limiters for transient stability Improvement based on difference between accelerating and decelerating areas

Tahere Daemi, Mahdi Dehghani-Ashkezari, Hamidreza Akbari, Mahmoud Modaresi, Seyedamin Saied
article en
2 citations

Abstract

The utilization of fault current limiters (FCLs) provides an effective approach to alleviate the negative consequences associated with short circuit currents. This equipment can affect other system specifications. In this paper, the effects of FCL on power system transient stability are investigated by a theoretical-comparative study. In this study, different FCL impedances (inductive and resistive) are analyzed and compared considering two locations for FCL installation and different locations of fault occurrence in a single-machine infinite bus system. To evaluate the power system's transient stability, the authors adopt an approach based on the equal area criterion, which calculates the difference between accelerating and decelerating areas. Another issue addressed in this article is the fault-clearing time effect on the power system's transient stability as FCL is installed in the power grid. The results have been confirmed through the use of MATLAB software.

HeliyonVol. 10(16)
Islamic Azad University South Tehran Branch (IR), Islamic Azad University, Yazd (IR)
Climate action
Openalex Percentile: Top 39%
HVDC Systems and Fault Protection
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Impact of inductive and resistive fault current limiters for transient stability Improvement based on difference between accelerating and decelerating areas — Tahere Daemi, Mahdi Dehghani-Ashkezari, et al. · Heliyon (2024) | TGRS Research Map | TGRS