Spray-assisted drop formation liquid-phase microextraction for the determination of sertraline in environmental water samples with matrix-matching calibration in GC–MS

Abstract Sertraline is used as an antidepressant drug for the treatment of psychiatric disorders, including anxiety and depression. In the current study, a simple and effective method was developed for the sensitive monitoring of sertraline in water samples using a GC–MS system. The spray-assisted droplet formation liquid-phase microextraction (SADF-LPME) method was used as a sample preparation method for the enrichment of analytes. Accordingly, dichloromethane was used as an extraction solvent and easily dispersed into a sample/standard solution using a lab-made modified spray device without using a dispersing solvent. The significant factors affecting the SADF-LPME efficiency, including sample pH, mixing conditions, extraction solvent type, and spray cycle, were univariately optimized to ascertain the extraction performance and applicability of the system. Under the optimized conditions, the plotted calibration curve of the method was linear in the range of 100.2–2011.7 µg/kg (mass-based standard preparation) with a good correlation coefficient ( R 2 ) of 0.9997. The detection and quantification limits of method were found to be 37.5 and 125 µg/kg, respectively. Validation of the method was successfully carried out using different tap water samples and applying a matrix-matching calibration strategy. The acceptable percent recoveries were recorded between 77.3 and 133.7%, with high repeatability. The recommended method is an alternative and fast extraction method with several advantages, including a simple experimental process, good dispersibility, and fast and superior extraction performance. It can be readily applicable to the monitoring and quantification of sertraline in tap water samples with good precision and accuracy.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Science & Technology
Published
2024-08-09
DOI
https://doi.org/10.1186/s40543-024-00459-9
Citations
6
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
1.41

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spray-assisted drop formation liquid-phase microextraction for the determination of sertraline in environmental water samples with matrix-matching calibration in GC–MS

Hilal Akbıyık, Sezgin Bakırdere, Meltem Şaylan, Gamze Dalgıç Bozyiğit et al.
6 citations
Journal of Analytical Science & Technology
Analytical chemistry methods development
1.41
article

Spray-assisted drop formation liquid-phase microextraction for the determination of sertraline in environmental water samples with matrix-matching calibration in GC–MS

Hilal Akbıyık, Sezgin Bakırdere, Meltem Şaylan, Gamze Dalgıç Bozyiğit, Buse Tuğba Zaman, Nagehan Kübra Zeytinci, Emine Tezgin
article en
6 citations

Abstract

Abstract Sertraline is used as an antidepressant drug for the treatment of psychiatric disorders, including anxiety and depression. In the current study, a simple and effective method was developed for the sensitive monitoring of sertraline in water samples using a GC–MS system. The spray-assisted droplet formation liquid-phase microextraction (SADF-LPME) method was used as a sample preparation method for the enrichment of analytes. Accordingly, dichloromethane was used as an extraction solvent and easily dispersed into a sample/standard solution using a lab-made modified spray device without using a dispersing solvent. The significant factors affecting the SADF-LPME efficiency, including sample pH, mixing conditions, extraction solvent type, and spray cycle, were univariately optimized to ascertain the extraction performance and applicability of the system. Under the optimized conditions, the plotted calibration curve of the method was linear in the range of 100.2–2011.7 µg/kg (mass-based standard preparation) with a good correlation coefficient ( R 2 ) of 0.9997. The detection and quantification limits of method were found to be 37.5 and 125 µg/kg, respectively. Validation of the method was successfully carried out using different tap water samples and applying a matrix-matching calibration strategy. The acceptable percent recoveries were recorded between 77.3 and 133.7%, with high repeatability. The recommended method is an alternative and fast extraction method with several advantages, including a simple experimental process, good dispersibility, and fast and superior extraction performance. It can be readily applicable to the monitoring and quantification of sertraline in tap water samples with good precision and accuracy.

Journal of Analytical Science & TechnologyVol. 15(1)
Turkish Academy of Sciences (TR), Yıldız Technical University (TR), Istanbul University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Clean water and sanitation
Openalex Percentile: Top 21%
Analytical chemistry methods development
1.41
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.