Utilizing a forced Van der Pol-Rayleigh-Helmholtz oscillator under heptamodal-frequency operations in Casimir force measurement

Abstract In this paper, Casimir force sensitivity is investigated by utilizing a micro-cantilever under the driving forces in heptamodal operations. A novel forced Van der Pol-Rayleigh-Helmholtz nonlinear oscillator model is developed to describe the nonlinear dynamics of the micro-cantilever which is subject to the excitation and Casimir forces simultaneously. Demonstrating the effectiveness of the heptamodal operations, single- and tetramodal-frequency excitation schemes are also applied separately to resonate the micro-cantilever at the fundamental and higher eigenmodes. The oscillation observables of the externally driven micro-cantilever are determined in the presence of the Casimir forces in the separation distance range of 200–800 nm. Remarkable variations in amplitude ratio, phase shift, and frequency shift for different effective masses of the micro-cantilever are explored for the higher eigenmodes. In the current work, the AFM micro-cantilever exhibits the amplitude response of 0.82 nm to Casimir force at the fourth eigenmode for the separation distance ranging between 200 and 300 nm. The stable frequency shifts ranging between 10 3 and 10 6 Hz are also observed at the first four eigenmodes for larger separation distances (above around 500 nm). Moreover, the maximum phase shift response of around 150 degrees at the sixth eigenmode is achieved using heptamodal-frequency excitation of the lightest micro-cantilever (3.6 × 10 −12 kg) at the separation distance of 200 nm. Thus, implementing heptamodal-frequency excitation schemes has considerable potential to improve the phase shift sensitivity to Casimir forces when compared with other excitation schemes. Additionally, the parameters of the nonlinear oscillator significantly determine the patterns of the time-domain sensitivities to the external forces. Correspondingly, displacements of the micro-cantilever under the driving and Casimir forces at different eigenmodes are obtained to investigate diverse system nonlinearities. Furthermore, the virial and dissipated power are also determined for different effective masses of the micro-cantilever to explain the energy dissipation process in the measurement of Casimir forces. Therefore, in the present work, the observable responses and energy quantities for particular system nonlinearities are introduced to be utilized for nanometrological applications.

Authors

Institutions

Publication Details

Journal
Indian Journal of Physics
Published
2024-08-09
DOI
https://doi.org/10.1007/s12648-024-03359-1
Citations
3
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilizing a forced Van der Pol-Rayleigh-Helmholtz oscillator under heptamodal-frequency operations in Casimir force measurement

Çağrı Yılmaz
3 citations
Indian Journal of Physics
Mechanical and Optical Resonators
1.01
article

Utilizing a forced Van der Pol-Rayleigh-Helmholtz oscillator under heptamodal-frequency operations in Casimir force measurement

Çağrı Yılmaz
article en
3 citations

Abstract

Abstract In this paper, Casimir force sensitivity is investigated by utilizing a micro-cantilever under the driving forces in heptamodal operations. A novel forced Van der Pol-Rayleigh-Helmholtz nonlinear oscillator model is developed to describe the nonlinear dynamics of the micro-cantilever which is subject to the excitation and Casimir forces simultaneously. Demonstrating the effectiveness of the heptamodal operations, single- and tetramodal-frequency excitation schemes are also applied separately to resonate the micro-cantilever at the fundamental and higher eigenmodes. The oscillation observables of the externally driven micro-cantilever are determined in the presence of the Casimir forces in the separation distance range of 200–800 nm. Remarkable variations in amplitude ratio, phase shift, and frequency shift for different effective masses of the micro-cantilever are explored for the higher eigenmodes. In the current work, the AFM micro-cantilever exhibits the amplitude response of 0.82 nm to Casimir force at the fourth eigenmode for the separation distance ranging between 200 and 300 nm. The stable frequency shifts ranging between 10 3 and 10 6 Hz are also observed at the first four eigenmodes for larger separation distances (above around 500 nm). Moreover, the maximum phase shift response of around 150 degrees at the sixth eigenmode is achieved using heptamodal-frequency excitation of the lightest micro-cantilever (3.6 × 10 −12 kg) at the separation distance of 200 nm. Thus, implementing heptamodal-frequency excitation schemes has considerable potential to improve the phase shift sensitivity to Casimir forces when compared with other excitation schemes. Additionally, the parameters of the nonlinear oscillator significantly determine the patterns of the time-domain sensitivities to the external forces. Correspondingly, displacements of the micro-cantilever under the driving and Casimir forces at different eigenmodes are obtained to investigate diverse system nonlinearities. Furthermore, the virial and dissipated power are also determined for different effective masses of the micro-cantilever to explain the energy dissipation process in the measurement of Casimir forces. Therefore, in the present work, the observable responses and energy quantities for particular system nonlinearities are introduced to be utilized for nanometrological applications.

Indian Journal of PhysicsVol. 99(3)
Akdeniz University (TR)
Akdeniz Üniversitesi
Affordable and clean energy
Openalex Percentile: Top 25%
Mechanical and Optical Resonators
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.