An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity
State-of-the-art optical cavities are pivotal in pushing the envelope of laser frequency stability below 10-16. This is often achieved by extending the cavity length or cooling the system to cryogenic temperatures to reduce the thermal noise floor. In our study, we present a 30-cm-long cavity that operates at room temperature and is outfitted with crystalline coatings. The system has a predicted ultralow thermal noise floor of 4.4 × 10-17, comparable to what is observed in cryogenic silicon cavities. A 1397-nm laser is stabilized in this advanced cavity, and the stable frequency is then transferred to the clock transition in strontium optical lattice clocks via a frequency-doubling process. We have meticulously minimized and assessed the technical noise contributions through comparisons with an ultrastable reference laser that is locked to a commercially available 30-cm cavity. The frequency instability of the system is rigorously evaluated using a three-cornered-hat method. The results demonstrate that the laser frequency instability remains below 2 × 10-16 for averaging times ranging from 1 to 50 s. These findings underscore the significant potential of room-temperature cavities with crystalline coatings in high-precision metrology and pave the way for further improvements in optical lattice clocks.
Authors
- Ping Xu (ORCID: https://orcid.org/0000-0003-1508-4609)
- Yu-Ao Chen (ORCID: https://orcid.org/0000-0002-2309-2281)
- Xing-Yang Cui (ORCID: https://orcid.org/0009-0006-4774-3460)
- Han-Ning Dai (ORCID: https://orcid.org/0000-0003-0916-7942)
- Jian-Wei Pan (ORCID: https://orcid.org/0000-0002-6100-5142)
- Xiao Jiang (ORCID: https://orcid.org/0000-0002-1026-5075)
- De-Quan Kong (ORCID: https://orcid.org/0009-0009-3926-5341)
- Xibo Zhang (ORCID: https://orcid.org/0000-0002-0021-2412)
- Qiang Zhang (ORCID: https://orcid.org/0000-0002-5387-1921)
- Xiu-Ping Xie
- Hai-Wei Yu
- Ming-Yang Zheng (ORCID: https://orcid.org/0009-0005-9061-8852)
- Xian-Qing Zhu (ORCID: https://orcid.org/0009-0004-3141-9848)
- Xiaomin Zhai
Institutions
- University of Science and Technology of China (CN)
- Hefei National Center for Physical Sciences at Nanoscale (CN)
- Jinan Institute of Quantum Technology (CN)
- Beijing Academy of Quantum Information Sciences (CN)
Publication Details
- Journal
- Review of Scientific Instruments
- Published
- 2024-08-01
- DOI
- https://doi.org/10.1063/5.0200553
- Citations
- 11
- Primary Topic
- Advanced Frequency and Time Standards
- Type
- article
- Field-Weighted Citation Impact
- 3.71
Funders
- National Natural Science Foundation of China
- Shanghai Rising-Star Program
- National Key Research and Development Program of China