An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity

State-of-the-art optical cavities are pivotal in pushing the envelope of laser frequency stability below 10-16. This is often achieved by extending the cavity length or cooling the system to cryogenic temperatures to reduce the thermal noise floor. In our study, we present a 30-cm-long cavity that operates at room temperature and is outfitted with crystalline coatings. The system has a predicted ultralow thermal noise floor of 4.4 × 10-17, comparable to what is observed in cryogenic silicon cavities. A 1397-nm laser is stabilized in this advanced cavity, and the stable frequency is then transferred to the clock transition in strontium optical lattice clocks via a frequency-doubling process. We have meticulously minimized and assessed the technical noise contributions through comparisons with an ultrastable reference laser that is locked to a commercially available 30-cm cavity. The frequency instability of the system is rigorously evaluated using a three-cornered-hat method. The results demonstrate that the laser frequency instability remains below 2 × 10-16 for averaging times ranging from 1 to 50 s. These findings underscore the significant potential of room-temperature cavities with crystalline coatings in high-precision metrology and pave the way for further improvements in optical lattice clocks.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-08-01
DOI
https://doi.org/10.1063/5.0200553
Citations
11
Primary Topic
Advanced Frequency and Time Standards
Type
article
Field-Weighted Citation Impact
3.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity

Ping Xu, Yu-Ao Chen, Xing-Yang Cui, Han-Ning Dai et al.
11 citations
Review of Scientific Instruments
Advanced Frequency and Time Standards
3.71
article

An ultrastable 1397-nm laser stabilized by a crystalline-coated room-temperature cavity

Ping Xu, Yu-Ao Chen, Xing-Yang Cui, Han-Ning Dai, Jian-Wei Pan, Xiao Jiang, De-Quan Kong, Xibo Zhang, Qiang Zhang, Xiu-Ping Xie, Hai-Wei Yu, Ming-Yang Zheng, Xian-Qing Zhu, Xiaomin Zhai
article en
11 citations

Abstract

State-of-the-art optical cavities are pivotal in pushing the envelope of laser frequency stability below 10-16. This is often achieved by extending the cavity length or cooling the system to cryogenic temperatures to reduce the thermal noise floor. In our study, we present a 30-cm-long cavity that operates at room temperature and is outfitted with crystalline coatings. The system has a predicted ultralow thermal noise floor of 4.4 × 10-17, comparable to what is observed in cryogenic silicon cavities. A 1397-nm laser is stabilized in this advanced cavity, and the stable frequency is then transferred to the clock transition in strontium optical lattice clocks via a frequency-doubling process. We have meticulously minimized and assessed the technical noise contributions through comparisons with an ultrastable reference laser that is locked to a commercially available 30-cm cavity. The frequency instability of the system is rigorously evaluated using a three-cornered-hat method. The results demonstrate that the laser frequency instability remains below 2 × 10-16 for averaging times ranging from 1 to 50 s. These findings underscore the significant potential of room-temperature cavities with crystalline coatings in high-precision metrology and pave the way for further improvements in optical lattice clocks.

Review of Scientific InstrumentsVol. 95(8)
University of Science and Technology of China (CN), Hefei National Center for Physical Sciences at Nanoscale (CN), Jinan Institute of Quantum Technology (CN), Beijing Academy of Quantum Information Sciences (CN)
National Natural Science Foundation of China, Shanghai Rising-Star Program, National Key Research and Development Program of China
Sustainable cities and communities
Openalex Percentile: Top 6%
Advanced Frequency and Time Standards
3.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.