Realizing optimal radiative cooling walls in building-energy nexus via asymmetric emissivity

With the gradually warming climate, the global cooling demand for buildings is rapidly increasing. Radiative cooling (RC) has been an attractive electricity-free approach to reducing the energy consumption of buildings. Current RC strategies focus on roofs; however, limited attention has been paid to vertical walls. Here, we report a zigzag-based structural design with asymmetric emissivity to realize optimal RC walls. Such asymmetry leads to a daily average temperature drop of 2.3°C compared to conventional walls coated with RC materials. When the ground is at ∼56°C, the temperature drop reaches 3.1°C, corresponding to a relative cooling power of 67 W m−2 compared to the control wall. Moreover, the energy impact of this zigzag wall in diverse climate conditions is analyzed based on building-scale simulations. Current limitations and future improvement directions are also discussed. This zigzag RC wall provides a new passive solution to energy-efficient buildings.

Authors

Institutions

Publication Details

Journal
Nexus
Published
2024-08-09
DOI
https://doi.org/10.1016/j.ynexs.2024.100028
Citations
43
Primary Topic
Thermal Radiation and Cooling Technologies
Type
article
Field-Weighted Citation Impact
11.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Realizing optimal radiative cooling walls in building-energy nexus via asymmetric emissivity

Peter Zhang, Qilong Cheng, Jyotirmoy Mandal, X. Chen et al.
43 citations
Nexus
Thermal Radiation and Cooling Technologies
11.22
article

Realizing optimal radiative cooling walls in building-energy nexus via asymmetric emissivity

Peter Zhang, Qilong Cheng, Jyotirmoy Mandal, X. Chen, Yuan Yang, Nanfang Yu, Sebastián Gómez, Aaswath P. Raman, Albatool Abaalkhail, Jazmyn E. Beasley, Guanzhong Hu, Steven Tian, Yuan Xu
article en
43 citations

Abstract

With the gradually warming climate, the global cooling demand for buildings is rapidly increasing. Radiative cooling (RC) has been an attractive electricity-free approach to reducing the energy consumption of buildings. Current RC strategies focus on roofs; however, limited attention has been paid to vertical walls. Here, we report a zigzag-based structural design with asymmetric emissivity to realize optimal RC walls. Such asymmetry leads to a daily average temperature drop of 2.3°C compared to conventional walls coated with RC materials. When the ground is at ∼56°C, the temperature drop reaches 3.1°C, corresponding to a relative cooling power of 67 W m−2 compared to the control wall. Moreover, the energy impact of this zigzag wall in diverse climate conditions is analyzed based on building-scale simulations. Current limitations and future improvement directions are also discussed. This zigzag RC wall provides a new passive solution to energy-efficient buildings.

NexusVol. 1(3)
University of California, Los Angeles (US), Palo Alto University (US), Princeton University (US), Columbia University (US)
Affordable and clean energy
Openalex Percentile: Top 1%
Thermal Radiation and Cooling Technologies
11.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Realizing optimal radiative cooling walls in building-energy nexus via asymmetric emissivity — Peter Zhang, Qilong Cheng, et al. · Nexus (2024) | TGRS Research Map | TGRS