Optimizing Low-Temperature Three-Circuit Evaporative Cooling System for an Electric Motor by Using Refrigerants

This article presents modeling results and a comprehensive analysis of evaporative cooling systems designed for electric motors using the refrigerants R744 (trans-critical), R134a, R600a, and R290. This study aims to determine the most suitable refrigerant for use in a cooling system, optimize the system design, and calculate the maximum achievable motor power while adhering to specified temperature constraints. The modeling was validated by an experimental setup, which had the cooling system’s configuration featuring three circuits for motor housing, stator, and rotor cooling, respectively. The modeling of an evaporative system was used to present the cooling efficiency under varying loads and external temperature conditions. Mathematical modeling encompasses complex algorithms to simulate heat transfer phenomena, accounting for fluid dynamics and refrigeration cycle dynamics. The analyses revealed trends in winding temperature, rotor temperature, air temperature inside the motor, heat transfer coefficient, coefficient of performance (COP), and motor power across different operating conditions while using different cooling refrigerants. The maximal heat transfer coefficients were calculated for all the refrigerants for winding temperatures in the range from 32 to 82 °C, while air temperature and rotor temperatures were between 42 and 105 °C and 76 and 185 °C, respectively. Lowering the evaporation temperature of the coolant to −35 °C resulted in a significant decrease in the winding temperature to 15 °C, air temperature to 38 °C, and maximum rotor temperature to 118 °C at a motor power of 90 kW. Refrigerant R744 emerged as a promising option, offering high heat transfer coefficients and achieving high motor power within temperature limits. At the same time, the COP was lower when compared with other working fluids because of the high ambient temperature on the gas cooler side.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-08-09
DOI
https://doi.org/10.3390/en17163942
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Low-Temperature Three-Circuit Evaporative Cooling System for an Electric Motor by Using Refrigerants

Yuhiro Iwamoto, Jacob Joseph Lamb, Halina Kobalava, Ignat Tolstorebrov et al.
1 citations
Energies
Refrigeration and Air Conditioning Technologies
0.21
article

Optimizing Low-Temperature Three-Circuit Evaporative Cooling System for an Electric Motor by Using Refrigerants

Yuhiro Iwamoto, Jacob Joseph Lamb, Halina Kobalava, Ignat Tolstorebrov, Trygve Magne Eikevik, Dmytro Konovalov
article en
1 citations

Abstract

This article presents modeling results and a comprehensive analysis of evaporative cooling systems designed for electric motors using the refrigerants R744 (trans-critical), R134a, R600a, and R290. This study aims to determine the most suitable refrigerant for use in a cooling system, optimize the system design, and calculate the maximum achievable motor power while adhering to specified temperature constraints. The modeling was validated by an experimental setup, which had the cooling system’s configuration featuring three circuits for motor housing, stator, and rotor cooling, respectively. The modeling of an evaporative system was used to present the cooling efficiency under varying loads and external temperature conditions. Mathematical modeling encompasses complex algorithms to simulate heat transfer phenomena, accounting for fluid dynamics and refrigeration cycle dynamics. The analyses revealed trends in winding temperature, rotor temperature, air temperature inside the motor, heat transfer coefficient, coefficient of performance (COP), and motor power across different operating conditions while using different cooling refrigerants. The maximal heat transfer coefficients were calculated for all the refrigerants for winding temperatures in the range from 32 to 82 °C, while air temperature and rotor temperatures were between 42 and 105 °C and 76 and 185 °C, respectively. Lowering the evaporation temperature of the coolant to −35 °C resulted in a significant decrease in the winding temperature to 15 °C, air temperature to 38 °C, and maximum rotor temperature to 118 °C at a motor power of 90 kW. Refrigerant R744 emerged as a promising option, offering high heat transfer coefficients and achieving high motor power within temperature limits. At the same time, the COP was lower when compared with other working fluids because of the high ambient temperature on the gas cooler side.

EnergiesVol. 17(16)
Admiral Makarov National University of Shipbuilding (UA), Nagoya Institute of Technology (JP), Norwegian University of Science and Technology (NO)
Norges Forskningsråd
Affordable and clean energy
Openalex Percentile: Top 53%
Refrigeration and Air Conditioning Technologies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.