The use of Dose Management Systems in Europe: Results of an ESR EuroSafe Imaging Questionnaire

Dose management systems (DMS) are an essential tool for quality assurance and optimising patient radiation exposure. For radiologists and medical physicists, they are important for managing many radiation protection tasks. In addition, they help fulfil the requirements of Directive 2013/59/EURATOM regarding the electronic transmission of dosimetric data and the detection of unintended patient exposures. The EuroSafe Imaging Clinical Dosimetry and Dose Management Working Group launched a questionnaire on the use of DMS in European member states and analysed the results in terms of modalities, frequency of radiological procedures, involvement of medical physics experts (MPEs), legal requirements, and local issues (support by information technology (IT), modality interfaces, protocol mapping, clinical workflow, and associated costs). CRITICAL RELEVANCE STATEMENT: Despite the great advantages of dose management systems for optimising radiation protection, distribution remains insufficient. This questionnaire shows that reasons include: a lack of DICOM interfaces, insufficient harmonisation of procedure names, lack of medical physicist and IT support, and costs. KEY POINTS: Quantitative radiation dose information is essential for justification and optimisation in medical imaging. Guidelines are required to ensure radiation dose management systems quality and for acceptance testing. Verifying dose data management is crucial before dose management systems clinical implementation. Medical physics experts are professionals who have important responsibilities for the proper management of dose monitoring.

Authors

Institutions

Publication Details

Journal
Insights into Imaging
Published
2024-08-09
DOI
https://doi.org/10.1186/s13244-024-01765-x
Citations
7
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
2.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The use of Dose Management Systems in Europe: Results of an ESR EuroSafe Imaging Questionnaire

Graciano Paulo, Virginia Tsapaki, Hugues Brat, Guy Frija et al.
7 citations
Insights into Imaging
Radiation Dose and Imaging
2.83
article

The use of Dose Management Systems in Europe: Results of an ESR EuroSafe Imaging Questionnaire

Graciano Paulo, Virginia Tsapaki, Hugues Brat, Guy Frija, E. Vañó, Riccardo Corridori, Jonathan P McNulty, Boris Brkljačić, Claudio Granata, Jonas Andersson, Josefin Ammon, Christoph Hoeschen, Ivana Kralik, Timo De Bondt, John Damilakis, Elmar Kotter, Katrina Caikovska, R. Loose
article en
7 citations

Abstract

Dose management systems (DMS) are an essential tool for quality assurance and optimising patient radiation exposure. For radiologists and medical physicists, they are important for managing many radiation protection tasks. In addition, they help fulfil the requirements of Directive 2013/59/EURATOM regarding the electronic transmission of dosimetric data and the detection of unintended patient exposures. The EuroSafe Imaging Clinical Dosimetry and Dose Management Working Group launched a questionnaire on the use of DMS in European member states and analysed the results in terms of modalities, frequency of radiological procedures, involvement of medical physics experts (MPEs), legal requirements, and local issues (support by information technology (IT), modality interfaces, protocol mapping, clinical workflow, and associated costs). CRITICAL RELEVANCE STATEMENT: Despite the great advantages of dose management systems for optimising radiation protection, distribution remains insufficient. This questionnaire shows that reasons include: a lack of DICOM interfaces, insufficient harmonisation of procedure names, lack of medical physicist and IT support, and costs. KEY POINTS: Quantitative radiation dose information is essential for justification and optimisation in medical imaging. Guidelines are required to ensure radiation dose management systems quality and for acceptance testing. Verifying dose data management is crucial before dose management systems clinical implementation. Medical physics experts are professionals who have important responsibilities for the proper management of dose monitoring.

Insights into ImagingVol. 15(1)
University College Dublin (IE), Universidad Complutense de Madrid (ES), University of Crete (GR), University of Freiburg (DE), University of Zagreb (HR), Université Paris Cité (FR), IRCCS Materno Infantile Burlo Garofolo (IT), University Hospital Dubrava (HR), Polytechnic Institute of Coimbra (PT), Nuremberg Hospital (DE), Escola Superior de Tecnologia da Saúde de Coimbra (PT), Children's Clinical University Hospital (LV), European Coordination Committee of the Radiological, Electromedical and Healthcare IT Industry (BE), Agia Olga Hospital (GR), Umeå University (SE), Otto-von-Guericke-Universität Magdeburg (DE)
Partnerships for the goals
Openalex Percentile: Top 9%
Radiation Dose and Imaging
2.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.