Use of different designed needle-free connectors: a snapshot of central venous catheter intraluminal blood occlusion and central line–associated bloodstream infection in hospitals

Background: Needle-free connectors (NCs), originally designed to improve the safety of healthcare workers, are increasingly being used to mitigate central line–associated bloodstream infection (CLABSI) and central venous catheter intraluminal blood occlusion (CVC-IBO) in patients. There are numerous NCs on the market, with varied internal and external designs and features. Objectives: The purpose of this study was to compare the frequency, clinical, and financial impact of CVC-IBO and CLABSI among 16 California (USA) hospitals using differently designed NCs. Method: Data were collected by sending a survey to the hospitals, which had varying bed capacities and patient populations that were committed to reducing CVC-IBO and CLABSI. In each hospital, CLABSI rates were tracked as defined by the National Healthcare Safety Network. Results: Hospitals using the BD MaxPlus™ or MaxZero™ Needle-free Connector, the only device with a solid external access surface, were found to have a significantly lower CLABSI rate (1.32 vs. 2.95 per 1,000 central-line days [CLDs]; P = 0.0052) and CVC-IBO rate (1.51 vs. 4.04 per 1,000 CLDs; P = 0.0065) versus those using devices with a nonsolid access surface. Conclusion: Hospitals using the MaxPlus™ or MaxZero™ NC also had significantly higher cost saving (per 100 patient days) associated with lower use of tissue plasminogen activator versus devices with a nonsolid access surface ($219 vs. $510 USD; P = 0.01). These results highlight the clinical importance of NC design components and their contributions to risk of CLABSI and catheter occlusion.

Authors

Institutions

Publication Details

Journal
International journal of infection control
Published
2024-08-09
DOI
https://doi.org/10.3396/ijic.v20.23731
Citations
1
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of different designed needle-free connectors: a snapshot of central venous catheter intraluminal blood occlusion and central line–associated bloodstream infection in hospitals

Victor R. Lange
1 citations
International journal of infection control
Central Venous Catheters and Hemodialysis
0.74
article

Use of different designed needle-free connectors: a snapshot of central venous catheter intraluminal blood occlusion and central line–associated bloodstream infection in hospitals

Victor R. Lange
article en
1 citations

Abstract

Background: Needle-free connectors (NCs), originally designed to improve the safety of healthcare workers, are increasingly being used to mitigate central line–associated bloodstream infection (CLABSI) and central venous catheter intraluminal blood occlusion (CVC-IBO) in patients. There are numerous NCs on the market, with varied internal and external designs and features. Objectives: The purpose of this study was to compare the frequency, clinical, and financial impact of CVC-IBO and CLABSI among 16 California (USA) hospitals using differently designed NCs. Method: Data were collected by sending a survey to the hospitals, which had varying bed capacities and patient populations that were committed to reducing CVC-IBO and CLABSI. In each hospital, CLABSI rates were tracked as defined by the National Healthcare Safety Network. Results: Hospitals using the BD MaxPlus™ or MaxZero™ Needle-free Connector, the only device with a solid external access surface, were found to have a significantly lower CLABSI rate (1.32 vs. 2.95 per 1,000 central-line days [CLDs]; P = 0.0052) and CVC-IBO rate (1.51 vs. 4.04 per 1,000 CLDs; P = 0.0065) versus those using devices with a nonsolid access surface. Conclusion: Hospitals using the MaxPlus™ or MaxZero™ NC also had significantly higher cost saving (per 100 patient days) associated with lower use of tissue plasminogen activator versus devices with a nonsolid access surface ($219 vs. $510 USD; P = 0.01). These results highlight the clinical importance of NC design components and their contributions to risk of CLABSI and catheter occlusion.

International journal of infection controlVol. 20
Valley Medical Center (US)
Openalex Percentile: Top 29%
Central Venous Catheters and Hemodialysis
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Use of different designed needle-free connectors: a snapshot of central venous catheter intraluminal blood occlusion and central line–associated bloodstream infection in hospitals — Victor R. Lange · International journal of infection control (2024) | TGRS Research Map | TGRS