Protection System on Connect Panel for Use 7KT Smart Multi Function Meter Based on PLC and HMI via Modbus RTU Communication

One function of the protection system is to avoid or reduce damage to electrical equipment due to abnormal conditions such as undervoltage, overvoltage, overcurrent, underfrequency and harmonics. This protection system requires a Smart 7KT Multi-Function Meter and a PLC. Where the Smart 7KT Multi-Function Meter is used for monitoring then transferred to the PLC and detecting any abnormalities in the system when a disturbance occurs then the Smart 7KT Multi-Function Meter will send data to the PLC, then send a signal to the circuit breaker to disconnect the network that is experiencing disturbance. While the PLC is used to execute data that has been taken by the Multi-function Meter Smart 7KT for control or control on the Multi-function Meter Smart 7KT. When a disturbance occurs, the program on the PLC will protect and the type of disturbance will be displayed on the HMI screen. The results of this project were successful in securing undervoltage disturbances of 314.2 V for line voltages, overvoltage of 412.1 V for line voltages, overcurrent of 1.6 A, and testing of THD voltage between phases V12 of 1.3%, THD V23 of 1.1%, and THD V13 of 1.1%, for THD currents of 14.6% for THD I1, THD I2 of 9.4%, and THD I3 of 10.6% which occur in the electric power installation network which causes damage to electrical equipment.

Authors

Publication Details

Journal
International Journal of Multidisciplinary Approach Research and Science
Published
2024-08-09
DOI
https://doi.org/10.59653/ijmars.v2i03.1097
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Protection System on Connect Panel for Use 7KT Smart Multi Function Meter Based on PLC and HMI via Modbus RTU Communication

Basuki Winarno, Budi Triyono, Yuli Adam Prasetyo, Dimas Nur
International Journal of Multidisciplinary Approach Research and Science
Islanding Detection in Power Systems
article

Protection System on Connect Panel for Use 7KT Smart Multi Function Meter Based on PLC and HMI via Modbus RTU Communication

Basuki Winarno, Budi Triyono, Yuli Adam Prasetyo, Dimas Nur
article en

Abstract

One function of the protection system is to avoid or reduce damage to electrical equipment due to abnormal conditions such as undervoltage, overvoltage, overcurrent, underfrequency and harmonics. This protection system requires a Smart 7KT Multi-Function Meter and a PLC. Where the Smart 7KT Multi-Function Meter is used for monitoring then transferred to the PLC and detecting any abnormalities in the system when a disturbance occurs then the Smart 7KT Multi-Function Meter will send data to the PLC, then send a signal to the circuit breaker to disconnect the network that is experiencing disturbance. While the PLC is used to execute data that has been taken by the Multi-function Meter Smart 7KT for control or control on the Multi-function Meter Smart 7KT. When a disturbance occurs, the program on the PLC will protect and the type of disturbance will be displayed on the HMI screen. The results of this project were successful in securing undervoltage disturbances of 314.2 V for line voltages, overvoltage of 412.1 V for line voltages, overcurrent of 1.6 A, and testing of THD voltage between phases V12 of 1.3%, THD V23 of 1.1%, and THD V13 of 1.1%, for THD currents of 14.6% for THD I1, THD I2 of 9.4%, and THD I3 of 10.6% which occur in the electric power installation network which causes damage to electrical equipment.

International Journal of Multidisciplinary Approach Research and ScienceVol. 2(03)
Affordable and clean energy
Openalex Percentile: Top 90%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Protection System on Connect Panel for Use 7KT Smart Multi Function Meter Based on PLC and HMI via Modbus RTU Communication — Basuki Winarno, Budi Triyono, et al. · International Journal of Multidisciplinary Approach Research and Science (2024) | TGRS Research Map | TGRS