Efficacy and safety of navigation robot-assisted versus conventional oblique lateral lumbar interbody fusion with internal fixation in the treatment of lumbar degenerative diseases: A retrospective study

Effective internal fixation with pedicle screw is a key factor in the success of lumbar fusion with internal fixation. Whether navigation robots can improve the efficacy and safety of screw placement is controversial. Thirty-eight patients who underwent oblique lateral lumbar interbody fusion internal fixation from March 2022 to May 2023 were retrospectively analyzed, 16 cases in the navigational robot group and 22 cases in the fluoroscopy group. Using visual analog score (VAS) for the low back and lower limbs, Oswestry Disability Index to compare the clinical efficacy of the 2 groups; using perioperative indexes such as the duration of surgery, intraoperative blood loss, intraoperative fluoroscopy times, and postoperative hospital stay to compare the safety of the 2 groups; and using accuracy of pedicle screws (APS) and the facet joint violation (FJV) to compare the accuracy of the 2 groups. Postoperative follow-up at least 6 months, there was no statistically significant difference between the 2 groups in the baseline data (P > .05). The navigational robot group's VAS-back was significantly lower than the fluoroscopy group at 3 days postoperatively (P < .05). However, the differences between the 2 groups in VAS-back at 3 and 6 months postoperatively, and in VAS-leg and Oswestry Disability Index at 3 days, 3 months, and 6 months postoperatively were not significant (P > .05). Although duration of surgery in the navigational robot group was significantly longer than in the fluoroscopy group (P > .05), the intraoperative blood loss and the intraoperative fluoroscopy times were significantly lower than in the fluoroscopy group (P < .05). The difference in the PHS between the 2 groups was not significant (P > .05). The APS in the navigation robot group was significantly higher than in the fluoroscopy group, and the rate of FJV was significantly lower than in the fluoroscopy group (P < .05). Compared with the traditional fluoroscopic technique, navigation robot-assisted lumbar interbody fusion with internal fixation provides less postoperative low back pain in the short term, with less trauma, less bleeding, and lower radiation exposure, as well as better APS and lower FJV, resulting in better clinical efficacy and safety.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2024-08-09
DOI
https://doi.org/10.1097/md.0000000000039261
Citations
5
Primary Topic
Spine and Intervertebral Disc Pathology
Type
article
Field-Weighted Citation Impact
2.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and safety of navigation robot-assisted versus conventional oblique lateral lumbar interbody fusion with internal fixation in the treatment of lumbar degenerative diseases: A retrospective study

Zhenyu Dong, Min Tong, Shida Li, Limin Mou et al.
5 citations
Medicine
Spine and Intervertebral Disc Pathology
2.12
article

Efficacy and safety of navigation robot-assisted versus conventional oblique lateral lumbar interbody fusion with internal fixation in the treatment of lumbar degenerative diseases: A retrospective study

Zhenyu Dong, Min Tong, Shida Li, Limin Mou, Wenhao Zhang, Huang Yi-fei, Siping Zhang, Rong Wang
article en
5 citations

Abstract

Effective internal fixation with pedicle screw is a key factor in the success of lumbar fusion with internal fixation. Whether navigation robots can improve the efficacy and safety of screw placement is controversial. Thirty-eight patients who underwent oblique lateral lumbar interbody fusion internal fixation from March 2022 to May 2023 were retrospectively analyzed, 16 cases in the navigational robot group and 22 cases in the fluoroscopy group. Using visual analog score (VAS) for the low back and lower limbs, Oswestry Disability Index to compare the clinical efficacy of the 2 groups; using perioperative indexes such as the duration of surgery, intraoperative blood loss, intraoperative fluoroscopy times, and postoperative hospital stay to compare the safety of the 2 groups; and using accuracy of pedicle screws (APS) and the facet joint violation (FJV) to compare the accuracy of the 2 groups. Postoperative follow-up at least 6 months, there was no statistically significant difference between the 2 groups in the baseline data (P > .05). The navigational robot group's VAS-back was significantly lower than the fluoroscopy group at 3 days postoperatively (P < .05). However, the differences between the 2 groups in VAS-back at 3 and 6 months postoperatively, and in VAS-leg and Oswestry Disability Index at 3 days, 3 months, and 6 months postoperatively were not significant (P > .05). Although duration of surgery in the navigational robot group was significantly longer than in the fluoroscopy group (P > .05), the intraoperative blood loss and the intraoperative fluoroscopy times were significantly lower than in the fluoroscopy group (P < .05). The difference in the PHS between the 2 groups was not significant (P > .05). The APS in the navigation robot group was significantly higher than in the fluoroscopy group, and the rate of FJV was significantly lower than in the fluoroscopy group (P < .05). Compared with the traditional fluoroscopic technique, navigation robot-assisted lumbar interbody fusion with internal fixation provides less postoperative low back pain in the short term, with less trauma, less bleeding, and lower radiation exposure, as well as better APS and lower FJV, resulting in better clinical efficacy and safety.

MedicineVol. 103(32)
Xinjiang Medical University (CN), Xinjiang Uygur Autonomous Region Uygur Medicine Hospital (CN)
Good health and well-being
Openalex Percentile: Top 13%
Spine and Intervertebral Disc Pathology
2.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.