Designing and Simulating an additive manufacturable liquid metal heat pipe for future fusion application

The feasibility of a radiatively cooled 3D-printable liquid metal heat pipe (HP) design is assessed. Using the design flexibility offered by 3D-printing, the design of the wick and geometry of the HP were optimised to meet the requirement of 20 MW / m 2 heat load for a HP placed in a 1.5 T magnetic field. COMSOL was used to assess the operational limits of the HP, the thermal stresses in the wall, the thermally radiated power, and various materials for the HP. The main parameters are the diameter and spacing of the screen wires and the emissivity, 200 μ m , 200 μ m and 0.86 respectively. Molybdenum was chosen as the wall material and lithium as the working fluid. The design was made in Siemens NX and then exported to COMSOL. From simulations it was concluded that a molybdenum HP with the final design was capable of handling a steady state heat load of 20 MW / m 2 . • The heat pipe design can withstand a peak steady state heat load of 20 MW/m 2 . • Heat pipe design possible due improvements in additive manufacturing of molybdenum. • The next step is to create and test the heat pipe in Magnum-PSI. • In the future, heat pipe divertor concepts can significantly improve replaceability.

Authors

Institutions

Publication Details

Journal
Fusion Engineering and Design
Published
2024-08-09
DOI
https://doi.org/10.1016/j.fusengdes.2024.114611
Citations
2
Primary Topic
Fusion materials and technologies
Type
article
Field-Weighted Citation Impact
0.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Designing and Simulating an additive manufacturable liquid metal heat pipe for future fusion application

Nick Maassen, Lukas Kaserer, Marco Bakker
2 citations
Fusion Engineering and Design
Fusion materials and technologies
0.23
article

Designing and Simulating an additive manufacturable liquid metal heat pipe for future fusion application

Nick Maassen, Lukas Kaserer, Marco Bakker
article en
2 citations

Abstract

The feasibility of a radiatively cooled 3D-printable liquid metal heat pipe (HP) design is assessed. Using the design flexibility offered by 3D-printing, the design of the wick and geometry of the HP were optimised to meet the requirement of 20 MW / m 2 heat load for a HP placed in a 1.5 T magnetic field. COMSOL was used to assess the operational limits of the HP, the thermal stresses in the wall, the thermally radiated power, and various materials for the HP. The main parameters are the diameter and spacing of the screen wires and the emissivity, 200 μ m , 200 μ m and 0.86 respectively. Molybdenum was chosen as the wall material and lithium as the working fluid. The design was made in Siemens NX and then exported to COMSOL. From simulations it was concluded that a molybdenum HP with the final design was capable of handling a steady state heat load of 20 MW / m 2 . • The heat pipe design can withstand a peak steady state heat load of 20 MW/m 2 . • Heat pipe design possible due improvements in additive manufacturing of molybdenum. • The next step is to create and test the heat pipe in Magnum-PSI. • In the future, heat pipe divertor concepts can significantly improve replaceability.

Fusion Engineering and DesignVol. 207
Universität Innsbruck (AT), Eindhoven University of Technology (NL)
Openalex Percentile: Top 52%
Fusion materials and technologies
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.