Hygrothermal assessment of three bio-based insulation systems for internal retrofitting solid masonry walls

The present project investigated the hygrothermal performance and risk of mould growth in solid masonry walls retrofitted internally with three diffusion-open bio-based insulation materials (two loose-fill cellulose and one hemp fibre), installed in test containers with controlled indoor climate. Focus was on bio-based insulation materials, as these are upcoming due to necessary CO 2 reductions and because the hygroscopic properties of bio-based materials are different from traditional insulation materials like mineral wool therefore, some manufacturers claim a vapour barrier is unnecessary, even in relatively cold climates. The project was a large experimental study in two reefer containers with reconfigured facades, in which solid masonry walls with embedded wooden elements were constructed. The study focused on the conditions in the masonry/insulation interface and in the embedded wooden elements. The effect of hydrophobization and different indoor moisture loads were also investigated. Moreover, the bio-based insulation systems were compared with a wall insulated with the traditional mineral wool and vapour barrier system. Relative humidity and temperature were measured at several locations in the test walls for 1 year and 9 months. Measurements show that exposed masonry walls retrofitted internally with diffusion-open bio-based insulation materials resulted in unacceptably high moisture levels (>80% RH over longer periods). Lower moisture levels were observed when the internal insulation was combined with hydrophobization against wind-driven rain, but unacceptably high moisture levels still occurred (60%–70% in summer and 95%–100% in winter in the interface). Hydrophobization reduced the moisture levels in the interface and embedded wooden elements only in walls facing southwest, which is the direction with the most wind-driven rain. Mould growth tests showed no growth in the interface in walls insulated with cellulose insulation (mycometer surface value <25). Meanwhile growth was found in all four walls insulated with hemp fibre matts (mycometer surface value >400).

Authors

Institutions

Publication Details

Journal
Journal of Building Physics
Published
2024-08-08
DOI
https://doi.org/10.1177/17442591241265503
Citations
6
Primary Topic
Hygrothermal properties of building materials
Type
article
Field-Weighted Citation Impact
1.59

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hygrothermal assessment of three bio-based insulation systems for internal retrofitting solid masonry walls

Eva B. Møller, Nickolaj Feldt Jensen, Carsten Rode, Kurt Kielsgaard Hansen
6 citations
Journal of Building Physics
Hygrothermal properties of building materials
1.59
article

Hygrothermal assessment of three bio-based insulation systems for internal retrofitting solid masonry walls

Eva B. Møller, Nickolaj Feldt Jensen, Carsten Rode, Kurt Kielsgaard Hansen
article en
6 citations

Abstract

The present project investigated the hygrothermal performance and risk of mould growth in solid masonry walls retrofitted internally with three diffusion-open bio-based insulation materials (two loose-fill cellulose and one hemp fibre), installed in test containers with controlled indoor climate. Focus was on bio-based insulation materials, as these are upcoming due to necessary CO 2 reductions and because the hygroscopic properties of bio-based materials are different from traditional insulation materials like mineral wool therefore, some manufacturers claim a vapour barrier is unnecessary, even in relatively cold climates. The project was a large experimental study in two reefer containers with reconfigured facades, in which solid masonry walls with embedded wooden elements were constructed. The study focused on the conditions in the masonry/insulation interface and in the embedded wooden elements. The effect of hydrophobization and different indoor moisture loads were also investigated. Moreover, the bio-based insulation systems were compared with a wall insulated with the traditional mineral wool and vapour barrier system. Relative humidity and temperature were measured at several locations in the test walls for 1 year and 9 months. Measurements show that exposed masonry walls retrofitted internally with diffusion-open bio-based insulation materials resulted in unacceptably high moisture levels (>80% RH over longer periods). Lower moisture levels were observed when the internal insulation was combined with hydrophobization against wind-driven rain, but unacceptably high moisture levels still occurred (60%–70% in summer and 95%–100% in winter in the interface). Hydrophobization reduced the moisture levels in the interface and embedded wooden elements only in walls facing southwest, which is the direction with the most wind-driven rain. Mould growth tests showed no growth in the interface in walls insulated with cellulose insulation (mycometer surface value <25). Meanwhile growth was found in all four walls insulated with hemp fibre matts (mycometer surface value >400).

Journal of Building PhysicsVol. 48(2)
Aalborg University (DK), Technical University of Denmark (DK)
Realdania, Miljøteknologisk Udviklings- og Demonstrationsprogram
Climate action
Openalex Percentile: Top 18%
Hygrothermal properties of building materials
1.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.