Dimensional reliability in CAD/CAM production of complete denture bases: A comparative study of milling and various 3D printing technologies
This study aims to assess the dimensional accuracy of complete denture bases fabricated from different CAD/CAM technologies and a conventional method, including milling (CNC), PolyJet (PJ), laser sintering (SLS), digital light processing (DLP), and injection molding (IM). It also examines the influence of the removal of technology-specific connectors or support structures when present. Denture base surfaces were digitized using a laboratory scanner, and virtual measurement points were calculated with tetrahedral reference geometries. Defined distances were measured in all spatial directions and compared to design data (p<0.05), revealing significant differences in sagittal (p=0.004), transversal (p<0.001), and vertical (p<0.001) dimensions. Connector removal had no significant impact for CNC but significantly affected DLP. All technologies yielded clinically acceptable results, with CNC milling demonstrating the best overall outcome.
Authors
- Isabel Lente
- Janosch Goob
- Oliver Schubert (ORCID: https://orcid.org/0000-0002-2630-2635)
- Tobias Graf
- Michael Stimmelmayr (ORCID: https://orcid.org/0000-0001-6906-0827)
- Josef SCHWEIGER
Institutions
- Goethe University Frankfurt (DE)
- LMU Klinikum (DE)
- Ludwig-Maximilians-Universität München (DE)
Publication Details
- Journal
- Dental Materials Journal
- Published
- 2024-08-09
- DOI
- https://doi.org/10.4012/dmj.2023-215
- Citations
- 11
- Primary Topic
- Dental materials and restorations
- Type
- article
- Field-Weighted Citation Impact
- 4.43