Fate and transport of chlorine dioxide: Modeling chlorine dioxide in water distribution systems

This study aims to conduct a comprehensive analysis of switching disinfectants from sodium hypochlorite bleach to chlorine dioxide (ClO<sub>2</sub>) in the water distribution system of Geyikbayiri, Antalya. For this purpose, bulk decay rates of ClO<sub>2</sub> at various water temperatures were determined in laboratory studies. The study revealed ClO<sub>2</sub> bulk decay rates of 0.12639 day<sup>-1</sup>, 0.17848 day<sup>-1</sup>, and 0.19621 day<sup>-1</sup> at temperatures 15°C, 20°C, and 30°C, respectively. The EPANET, a widely employed computer program for simulating the extended-period behavior of hydraulic and water quality in pressurized pipes, was utilized for the analysis of the fate and transport of ClO<sub>2</sub>. A hydraulic model was first developed, calibrated, and verified using distinct data sets. The Hazen-Williams friction coefficient of the PSA was determined to be 120 by the trial-and-error method with a mean absolute error (MAE) of 0.408 m. A ClO<sub>2</sub> model was then integrated with the calibrated and verified hydraulic model, revealing a wall decay rate of 0.01 m/day and an average MAE of 0.034 mg/l. After calibration and verification of the ClO<sub>2</sub> model, several management scenarios were developed, and ClO<sub>2</sub> dosing rates were determined. The study showed that ClO<sub>2</sub> dosing rates of 0.40 mg/l and 0.45 mg/l should be applied to keep ClO<sub>2</sub> concentrations within certain limits. PRACTITIONER POINTS: Disinfectants must maintain a sufficient residual in water distribution systems. Chlorine dioxide requires less contact time and is not affected by pH fluctuations. Modeling serves as a decision-making tool for the management of disinfectants. Bulk and wall decay rates of chlorine dioxide are crucial for management strategies. Chlorine dioxide is a good alternative as a disinfectant in such systems.

Authors

Institutions

Publication Details

Journal
Water Environment Research
Published
2024-08-01
DOI
https://doi.org/10.1002/wer.11094
Citations
3
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.94

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fate and transport of chlorine dioxide: Modeling chlorine dioxide in water distribution systems

Tuğba AKDENİZ, I. Ethem Karadirek, Batuhan Okumus, Ozlem Cansu‐Aldemir et al.
3 citations
Water Environment Research
Water Treatment and Disinfection
0.94
article

Fate and transport of chlorine dioxide: Modeling chlorine dioxide in water distribution systems

Tuğba AKDENİZ, I. Ethem Karadirek, Batuhan Okumus, Ozlem Cansu‐Aldemir, Asli Nur Rizvanoglu
article en
3 citations

Abstract

This study aims to conduct a comprehensive analysis of switching disinfectants from sodium hypochlorite bleach to chlorine dioxide (ClO<sub>2</sub>) in the water distribution system of Geyikbayiri, Antalya. For this purpose, bulk decay rates of ClO<sub>2</sub> at various water temperatures were determined in laboratory studies. The study revealed ClO<sub>2</sub> bulk decay rates of 0.12639 day<sup>-1</sup>, 0.17848 day<sup>-1</sup>, and 0.19621 day<sup>-1</sup> at temperatures 15°C, 20°C, and 30°C, respectively. The EPANET, a widely employed computer program for simulating the extended-period behavior of hydraulic and water quality in pressurized pipes, was utilized for the analysis of the fate and transport of ClO<sub>2</sub>. A hydraulic model was first developed, calibrated, and verified using distinct data sets. The Hazen-Williams friction coefficient of the PSA was determined to be 120 by the trial-and-error method with a mean absolute error (MAE) of 0.408 m. A ClO<sub>2</sub> model was then integrated with the calibrated and verified hydraulic model, revealing a wall decay rate of 0.01 m/day and an average MAE of 0.034 mg/l. After calibration and verification of the ClO<sub>2</sub> model, several management scenarios were developed, and ClO<sub>2</sub> dosing rates were determined. The study showed that ClO<sub>2</sub> dosing rates of 0.40 mg/l and 0.45 mg/l should be applied to keep ClO<sub>2</sub> concentrations within certain limits. PRACTITIONER POINTS: Disinfectants must maintain a sufficient residual in water distribution systems. Chlorine dioxide requires less contact time and is not affected by pH fluctuations. Modeling serves as a decision-making tool for the management of disinfectants. Bulk and wall decay rates of chlorine dioxide are crucial for management strategies. Chlorine dioxide is a good alternative as a disinfectant in such systems.

Water Environment ResearchVol. 96(8)
Akdeniz University (TR), Antalya IVF (TR)
Akdeniz Üniversitesi
Clean water and sanitation
Openalex Percentile: Top 25%
Water Treatment and Disinfection
0.94
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.