Robotic‐assisted laparoscopic radical nephrectomy and lymph nodes dissection using Senhance robotic system and Senhance ultrasonic energy device: A case report
Using the Senhance robotic system and Senhance ultrasonic energy device for robotic-assisted radical nephrectomy with hilum lymph node dissection demonstrated safety and feasibility in managing a large renal tumor without the need for open conversion or transfusion, offering a cost-effective solution.
Authors
- Kuan Chong Ng (ORCID: https://orcid.org/0009-0001-5577-8771)
- Lun‐Hsiang Yuan
Institutions
- National Taiwan University Hospital (TW)
- National Cheng Kung University (TW)
Publication Details
- Journal
- Clinical Case Reports
- Published
- 2024-08-01
- DOI
- https://doi.org/10.1002/ccr3.9117
- Citations
- 1
- Primary Topic
- Renal cell carcinoma treatment
- Type
- article
- Field-Weighted Citation Impact
- 0.42