Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study

We used finite element analysis to study the mechanical stress distribution of a new intramedullary implant used for proximal interphalangeal joint (PIPJ) arthrodesis (PIPJA) to surgically correct the claw-hammer toe deformity that affects 20% of the population. After geometric reconstruction of the foot skeleton from claw toe images of a 36-year-old male patient, two implants were positioned, in the virtual model, one neutral implant (NI) and another one 10° angled (10°AI) within the PIPJ of the second through fourth HT during the toe-off phase of gait and results were compared to those derived for the non-surgical foot (NSF). A PIPJA was performed on the second toe using a NI reduced tensile stress at the proximal phalanx (PP) (45.83 MPa) compared to the NSF (59.44 MPa; p < 0.001). When using the 10°AI, the tensile stress was much higher at PP and middle phalanges (MP) of the same toe, measuring 147.58 and 160.58 MPa, respectively, versus 59.44 and 74.95 MPa at corresponding joints in the NSF (all p < 0.001). Similar results were found for compressive stresses. The NI reduced compressive stress at the second PP (-65.12 MPa) compared to the NSF (-113.23 MPa) and the 10°AI (-142 MPa) (all p < 0.001). The von Mises stresses within the implant were also significantly lower when using NI versus 10°AI (p < 0.001). Therefore, we do not recommend performing a PIPJA using the 10°AI due to the increase in stress concentration primarily at the second PP and MP, which could promote implant breakage.

Authors

Institutions

Publication Details

Journal
International Wound Journal
Published
2024-08-01
DOI
https://doi.org/10.1111/iwj.70014
Citations
1
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study

Ricardo Vallejo, María Prados‐Privado, Juan Carlos Prados‐Frutos, Daniel López‐López et al.
1 citations
International Wound Journal
Orthopedic Surgery and Rehabilitation
0.57
article

Influence of the biomechanical evaluation of rupture using two shapes of same intramedullary implant after proximal interphalangeal joint arthrodesis to correct the claw/hammer pathology: A finite element study

Ricardo Vallejo, María Prados‐Privado, Juan Carlos Prados‐Frutos, Daniel López‐López, Marta Elena Losa‐Iglesias, Javier Bayod‐López
article en
1 citations

Abstract

We used finite element analysis to study the mechanical stress distribution of a new intramedullary implant used for proximal interphalangeal joint (PIPJ) arthrodesis (PIPJA) to surgically correct the claw-hammer toe deformity that affects 20% of the population. After geometric reconstruction of the foot skeleton from claw toe images of a 36-year-old male patient, two implants were positioned, in the virtual model, one neutral implant (NI) and another one 10° angled (10°AI) within the PIPJ of the second through fourth HT during the toe-off phase of gait and results were compared to those derived for the non-surgical foot (NSF). A PIPJA was performed on the second toe using a NI reduced tensile stress at the proximal phalanx (PP) (45.83 MPa) compared to the NSF (59.44 MPa; p < 0.001). When using the 10°AI, the tensile stress was much higher at PP and middle phalanges (MP) of the same toe, measuring 147.58 and 160.58 MPa, respectively, versus 59.44 and 74.95 MPa at corresponding joints in the NSF (all p < 0.001). Similar results were found for compressive stresses. The NI reduced compressive stress at the second PP (-65.12 MPa) compared to the NSF (-113.23 MPa) and the 10°AI (-142 MPa) (all p < 0.001). The von Mises stresses within the implant were also significantly lower when using NI versus 10°AI (p < 0.001). Therefore, we do not recommend performing a PIPJA using the 10°AI due to the increase in stress concentration primarily at the second PP and MP, which could promote implant breakage.

International Wound JournalVol. 21(8)
Universidade da Coruña (ES), Universidad Complutense de Madrid (ES), Universidad Rey Juan Carlos (ES), Universidad de Zaragoza (ES), Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES), Centro de Investigación Biomédica en Red (ES), Universidad Carlos III de Madrid (ES)
Universidade da Coruña
Openalex Percentile: Top 31%
Orthopedic Surgery and Rehabilitation
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.