In-Line Thermal Desorption and Dielectric Barrier Discharge Ionization for Rapid Mass Spectrometry Detection of Explosives

Thermal desorption (TD) of wipe-based samples was coupled with an in-line dielectric barrier discharge ionization (DBDI) source and rugged compact time-of-flight mass spectrometer (MS) for the detection of explosives, propellants, and postblast debris. The chromatography-free TD-DBDI-MS platform enabled rapid and sensitive detection of organic nitramine, nitrate ester, and nitroaromatic explosives as well as black powder and black powder substitute propellants. Parametric investigations characterized the response to TD temperature and optimized DBDI voltage, aerodynamically assisted entrainment, and fragmentation through in-source collision induced dissociation (isCID). Excess nitrate generated by the DBDI source yielded predominantly nitrate-adduct formation. Subnanogram sensitivities were demonstrated for all explosives investigated, except for nitroglycerin, specifically due to its volatility. Further, most analytes/explosives exhibited tens of picograms sensitivities. The platform also demonstrated the detection of propellant and military explosives from postblast debris. The TD-DBDI-MS system performed well without the need for aerodynamically assisted entrainment (and the associated rough pump), which along with requiring no additional gases (i.e., N<sub>2</sub> or He) or solvents, aid in potential field deployment. The ease of TD-DBDI attachment and removal added trace solid or liquid residue detection to the rugged mass spectrometer, designed primarily for the analysis of volatile organic and inorganic compounds.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-08-05
DOI
https://doi.org/10.1021/acs.analchem.4c02974
Citations
12
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.89

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-Line Thermal Desorption and Dielectric Barrier Discharge Ionization for Rapid Mass Spectrometry Detection of Explosives

Thomas P. Forbes, Elizabeth L. Robinson, Abigail R. Koss, Edward Sisco
12 citations
Analytical Chemistry
Mass Spectrometry Techniques and Applications
2.89
article

In-Line Thermal Desorption and Dielectric Barrier Discharge Ionization for Rapid Mass Spectrometry Detection of Explosives

Thomas P. Forbes, Elizabeth L. Robinson, Abigail R. Koss, Edward Sisco
article en
12 citations

Abstract

Thermal desorption (TD) of wipe-based samples was coupled with an in-line dielectric barrier discharge ionization (DBDI) source and rugged compact time-of-flight mass spectrometer (MS) for the detection of explosives, propellants, and postblast debris. The chromatography-free TD-DBDI-MS platform enabled rapid and sensitive detection of organic nitramine, nitrate ester, and nitroaromatic explosives as well as black powder and black powder substitute propellants. Parametric investigations characterized the response to TD temperature and optimized DBDI voltage, aerodynamically assisted entrainment, and fragmentation through in-source collision induced dissociation (isCID). Excess nitrate generated by the DBDI source yielded predominantly nitrate-adduct formation. Subnanogram sensitivities were demonstrated for all explosives investigated, except for nitroglycerin, specifically due to its volatility. Further, most analytes/explosives exhibited tens of picograms sensitivities. The platform also demonstrated the detection of propellant and military explosives from postblast debris. The TD-DBDI-MS system performed well without the need for aerodynamically assisted entrainment (and the associated rough pump), which along with requiring no additional gases (i.e., N<sub>2</sub> or He) or solvents, aid in potential field deployment. The ease of TD-DBDI attachment and removal added trace solid or liquid residue detection to the rugged mass spectrometer, designed primarily for the analysis of volatile organic and inorganic compounds.

Analytical ChemistryVol. 96(33)
National Institute of Standards and Technology (US), Material Measurement Laboratory (US)
Science and Technology Directorate
Openalex Percentile: Top 8%
Mass Spectrometry Techniques and Applications
2.89
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.