Voltammetric determination of a UV filter pollutant using a platinum electrode modified by a polymer membrane based on ß-cyclodextrin

Purpose This study aims to develop an electrochemical sensor for the detection of benzophenone (BP) as an alternative to conventional techniques that are known, expensive, complex and less sensitive. Design/methodology/approach The developed sensor is a platinum electrode modified with a plasticized polymer film based on ß-cyclodextrin, using PVC as the polymer, PEG as the plasticizer and ß-CD as the ionophore. This sensor is characterized by various techniques, such as optical microscopy, scanning electron microscopy and cyclic voltammetry. This latter is also used for analyzing kinetic processes at the electrode/electrolyte interface and to evaluate the selectivity and sensitivity of the sensor. Findings The results highlight the performance of our sensor. In fact, it exhibits a linear response extending from 10 −19 to 10 −13 M, with a correlation coefficient of 0.9836. What is more, it has an excellent detection limit of 10 −19 M and a good sensitivity of 21.24 µA/M. Originality/value The results of this investigation demonstrated that the developed sensor is an analytical tool of choice for the monitoring of BP in the aqueous phase. The suggested sensor is fast, simple, reproducible and inexpensive.

Authors

Institutions

Publication Details

Journal
Sensor Review
Published
2024-08-05
DOI
https://doi.org/10.1108/sr-05-2024-0494
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.29
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Voltammetric determination of a UV filter pollutant using a platinum electrode modified by a polymer membrane based on ß-cyclodextrin

Rim Lamari, Saida Zougar, Ilhem Ghodbane, Rochdi Kherrrat et al.
1 citations
Sensor Review
Analytical Chemistry and Sensors
0.29
article

Voltammetric determination of a UV filter pollutant using a platinum electrode modified by a polymer membrane based on ß-cyclodextrin

Rim Lamari, Saida Zougar, Ilhem Ghodbane, Rochdi Kherrrat, Roumaissa Laieb, Rahma Benyahia
article en
1 citations

Abstract

Purpose This study aims to develop an electrochemical sensor for the detection of benzophenone (BP) as an alternative to conventional techniques that are known, expensive, complex and less sensitive. Design/methodology/approach The developed sensor is a platinum electrode modified with a plasticized polymer film based on ß-cyclodextrin, using PVC as the polymer, PEG as the plasticizer and ß-CD as the ionophore. This sensor is characterized by various techniques, such as optical microscopy, scanning electron microscopy and cyclic voltammetry. This latter is also used for analyzing kinetic processes at the electrode/electrolyte interface and to evaluate the selectivity and sensitivity of the sensor. Findings The results highlight the performance of our sensor. In fact, it exhibits a linear response extending from 10 −19 to 10 −13 M, with a correlation coefficient of 0.9836. What is more, it has an excellent detection limit of 10 −19 M and a good sensitivity of 21.24 µA/M. Originality/value The results of this investigation demonstrated that the developed sensor is an analytical tool of choice for the monitoring of BP in the aqueous phase. The suggested sensor is fast, simple, reproducible and inexpensive.

Sensor ReviewVol. 44(6)
Badji Mokhtar-Annaba University (DZ)
Openalex Percentile: Top 50%
Analytical Chemistry and Sensors
0.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.