Illumination-adjustable photoacoustic and harmonic ultrasound for tracking magnetically driven microrobots

The development of microrobots for biomedical applications has enabled tasks such as targeted drug delivery, minimally invasive surgeries, and precise diagnostics. However, effective in vivo navigation and control remain challenging due to their small size and complex body environment. Photoacoustic (PA) and ultrasound (US) imaging techniques, which offer high contrast, high resolution, and deep tissue penetration, are integrated to enhance microrobot visualization and tracking. Traditional imaging systems have a narrow effective illumination area, suffer from severe reflection artifacts, and are affected by strong electromagnetic fields. To address this, we present an illumination-adjustable PA and harmonic US imaging system with a customized pushrod mechanism for real-time focus adjustment. Experiments demonstrate high-resolution imaging and accurate microrobot positioning, showcasing the potential for biomedical applications, especially in minimally invasive procedures.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2024-08-05
DOI
https://doi.org/10.1364/boe.535028
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Illumination-adjustable photoacoustic and harmonic ultrasound for tracking magnetically driven microrobots

Chunqi Zhang, Dong Sun, Chongyun Wang, Wah Shing Lam et al.
1 citations
Biomedical Optics Express
Photoacoustic and Ultrasonic Imaging
0.18
article

Illumination-adjustable photoacoustic and harmonic ultrasound for tracking magnetically driven microrobots

Chunqi Zhang, Dong Sun, Chongyun Wang, Wah Shing Lam, Han Zhao, Hanjin Huang
article en
1 citations

Abstract

The development of microrobots for biomedical applications has enabled tasks such as targeted drug delivery, minimally invasive surgeries, and precise diagnostics. However, effective in vivo navigation and control remain challenging due to their small size and complex body environment. Photoacoustic (PA) and ultrasound (US) imaging techniques, which offer high contrast, high resolution, and deep tissue penetration, are integrated to enhance microrobot visualization and tracking. Traditional imaging systems have a narrow effective illumination area, suffer from severe reflection artifacts, and are affected by strong electromagnetic fields. To address this, we present an illumination-adjustable PA and harmonic US imaging system with a customized pushrod mechanism for real-time focus adjustment. Experiments demonstrate high-resolution imaging and accurate microrobot positioning, showcasing the potential for biomedical applications, especially in minimally invasive procedures.

Biomedical Optics ExpressVol. 15(10)
Department of Health (CN), City University of Hong Kong (HK), Shenzhen Academy of Robotics (CN), City University of Hong Kong, Shenzhen Research Institute (CN)
National Natural Science Foundation of China, University Grants Committee, Science, Technology and Innovation Commission of Shenzhen Municipality
Affordable and clean energy
Openalex Percentile: Top 54%
Photoacoustic and Ultrasonic Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Illumination-adjustable photoacoustic and harmonic ultrasound for tracking magnetically driven microrobots — Chunqi Zhang, Dong Sun, et al. · Biomedical Optics Express (2024) | TGRS Research Map | TGRS