Successful transcatheter aortic valve replacement in a failing HAART 300 aortic valve annuloplasty ring: A case report

Transcutaneous aortic valve replacement (TAVR) has evolved from a complex procedure meant only for patients at prohibitive risk for surgery to a commonly performed procedure across a wide variety of clinical scenarios including the treatment of failed aortic valve bioprosthesis. Annuloplasty rings in the aortic position such as HAART 300 (Biostable Science and Engineering) have been introduced in the management of native aortic regurgitation. Percutaneous management of failed bioprosthesis rings in the aortic position has not been widely described. We present a case of a 69-year-old man with recurrent aortic regurgitation successfully treated with TAVR using a SAPIEN 3 valve within a HAART 300 ring.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2024-08-05
DOI
https://doi.org/10.1002/ccd.31177
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Successful transcatheter aortic valve replacement in a failing HAART 300 aortic valve annuloplasty ring: A case report

Alessandro El Khoury, Daniel McGrail, Omar Abdel‐Razek, Roger J. Laham
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

Successful transcatheter aortic valve replacement in a failing HAART 300 aortic valve annuloplasty ring: A case report

Alessandro El Khoury, Daniel McGrail, Omar Abdel‐Razek, Roger J. Laham
article en

Abstract

Transcutaneous aortic valve replacement (TAVR) has evolved from a complex procedure meant only for patients at prohibitive risk for surgery to a commonly performed procedure across a wide variety of clinical scenarios including the treatment of failed aortic valve bioprosthesis. Annuloplasty rings in the aortic position such as HAART 300 (Biostable Science and Engineering) have been introduced in the management of native aortic regurgitation. Percutaneous management of failed bioprosthesis rings in the aortic position has not been widely described. We present a case of a 69-year-old man with recurrent aortic regurgitation successfully treated with TAVR using a SAPIEN 3 valve within a HAART 300 ring.

Catheterization and Cardiovascular InterventionsVol. 104(3)
Beth Israel Deaconess Medical Center (US), Harvard University (US)
Good health and well-being
Openalex Percentile: Top 77%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.