Electrochemiluminescence Lateral Flow Immunoassay Using Ruthenium(II) Complex‐Loaded Dendritic Mesoporous Silica Nanospheres for Highly Sensitive and Quantitative Detection of SARS‐CoV‐2 Nucleocapsid Protein

Abstract Lateral flow immunoassays (LFIA) are widely used for the cost‐effective and rapid detection of diverse analytes. However, traditional LFIA suffers from difficulties in providing quantitative results and has low sensitivity. Herein, LFIA is combined with electrochemiluminescence (ECL), a leading transduction technique with high sensitivity and wide dynamic range, to achieve highly sensitive and quantitative detection of severe acute respiratory syndrome coronavirus nucleocapsid protein (SARS‐CoV‐2 N protein). Ruthenium(II)‐based complexes are synthesized and loaded into dendritic mesoporous silica nanospheres (PEI‐Ru/dSiO 2 ), which possessed central‐radial pore channels and served as tags for ECL‐LFIA. The electrodes are fabricated on a nitrocellulose (NC) membrane, which simplifies the structure of the ECL‐LFIA. PEI‐Ru/dSiO 2 is captured on the electrode surface via a sandwich immunoreaction, which enhances the ECL signal by decreasing the distance between PEI‐Ru/dSiO 2 and the electrode surface. Using 2,2‐bis(hydroxymethyl)‐2,2′,2′'‐nitrilotriethanol (BIS‐TRIS) as coreactant, the ECL‐LFIA is used for detecting SARS‐CoV‐2 N protein, with a linear range of 1–10 4 ng mL −1 and a limit of detection (LOD) of 0.52 ng mL −1 . ECL‐LFIA can also be used to detect analytes in complex matrices. These results demonstrate that the prepared ECL‐LFIA has great potential as a point‐of‐care testing platform for the rapid and quantitative detection of disease biomarkers.

Authors

Institutions

Publication Details

Journal
Advanced Functional Materials
Published
2024-08-05
DOI
https://doi.org/10.1002/adfm.202409632
Citations
38
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
8.89

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemiluminescence Lateral Flow Immunoassay Using Ruthenium(II) Complex‐Loaded Dendritic Mesoporous Silica Nanospheres for Highly Sensitive and Quantitative Detection of SARS‐CoV‐2 Nucleocapsid Protein

Wenxuan Fu, Xudong Ying, Ya-Feng Wang, Bin Su et al.
38 citations
Advanced Functional Materials
Advanced biosensing and bioanalysis techniques
8.89
article

Electrochemiluminescence Lateral Flow Immunoassay Using Ruthenium(II) Complex‐Loaded Dendritic Mesoporous Silica Nanospheres for Highly Sensitive and Quantitative Detection of SARS‐CoV‐2 Nucleocapsid Protein

Wenxuan Fu, Xudong Ying, Ya-Feng Wang, Bin Su, Tao Sun, Xuexue Wang, Jing Wang
article en
38 citations

Abstract

Abstract Lateral flow immunoassays (LFIA) are widely used for the cost‐effective and rapid detection of diverse analytes. However, traditional LFIA suffers from difficulties in providing quantitative results and has low sensitivity. Herein, LFIA is combined with electrochemiluminescence (ECL), a leading transduction technique with high sensitivity and wide dynamic range, to achieve highly sensitive and quantitative detection of severe acute respiratory syndrome coronavirus nucleocapsid protein (SARS‐CoV‐2 N protein). Ruthenium(II)‐based complexes are synthesized and loaded into dendritic mesoporous silica nanospheres (PEI‐Ru/dSiO 2 ), which possessed central‐radial pore channels and served as tags for ECL‐LFIA. The electrodes are fabricated on a nitrocellulose (NC) membrane, which simplifies the structure of the ECL‐LFIA. PEI‐Ru/dSiO 2 is captured on the electrode surface via a sandwich immunoreaction, which enhances the ECL signal by decreasing the distance between PEI‐Ru/dSiO 2 and the electrode surface. Using 2,2‐bis(hydroxymethyl)‐2,2′,2′'‐nitrilotriethanol (BIS‐TRIS) as coreactant, the ECL‐LFIA is used for detecting SARS‐CoV‐2 N protein, with a linear range of 1–10 4 ng mL −1 and a limit of detection (LOD) of 0.52 ng mL −1 . ECL‐LFIA can also be used to detect analytes in complex matrices. These results demonstrate that the prepared ECL‐LFIA has great potential as a point‐of‐care testing platform for the rapid and quantitative detection of disease biomarkers.

Advanced Functional MaterialsVol. 34(51)
Sir Run Run Shaw Hospital (CN), Second Affiliated Hospital of Zhejiang University (CN), Zhejiang University of Technology (CN), Zhejiang University (CN)
National Natural Science Foundation of China, Zhejiang University
Openalex Percentile: Top 1%
Advanced biosensing and bioanalysis techniques
8.89
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.