Insights into Spectral Distortion and Nonlinearity in UV–Vis and Fluorescence Spectroscopy of Molecular Fluorophore Solutions: Effects of Cascading Optical Processes (Part IV)

Reproducibility and linearity are crucial benchmarks for any measurement technology. However, UV-vis and fluorescence spectral distortion and nonlinearity are prevalent, even in seemingly simple fluorescent solutions that comprise only one dissolved molecular fluorophore, without exogenous absorbing or scattering species. In this report, we introduce an analytical model for the quantification of fluorescence interference on UV-vis measurements and a conceptual model for mechanistically understanding the impacts of higher-order cascading optical processes on fluorescence measurements. The experimental UV-vis transmittance can be dominated by interfering fluorescence, even for fluorophore solutions with theoretical absorbance values far below the instrument's linear dynamic range (LDR). Absorption-inner-filter-effect (aIFE) correction drastically improves the fluorescence LDR. However, the efficacy of aIFE correction hinges on two competing factors that strongly depend on the fluorophore's optical properties: the degree of fluorescence interference in UV-vis and the significance of secondary or higher-order emission triggered by fluorophore absorption of emitted photons. Our research sheds light on the remarkable complexity of cascading optical processes that can occur even in the simplest fluorescent solutions. It emphasizes the necessity of critically evaluating optical spectroscopic measurements of fluorescent solutions to improve the reliability of analyzing and interpreting optical spectra. Moreover, it lays the groundwork for future development of methods capable of handling challenging samples that exceed the capabilities of the current tools.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-08-05
DOI
https://doi.org/10.1021/acs.analchem.4c02173
Citations
3
Primary Topic
Protein Interaction Studies and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insights into Spectral Distortion and Nonlinearity in UV–Vis and Fluorescence Spectroscopy of Molecular Fluorophore Solutions: Effects of Cascading Optical Processes (Part IV)

Pathum Wathudura, Dongmao Zhang, Joshua McEachin
3 citations
Analytical Chemistry
Protein Interaction Studies and Fluorescence Analysis
0.70
article

Insights into Spectral Distortion and Nonlinearity in UV–Vis and Fluorescence Spectroscopy of Molecular Fluorophore Solutions: Effects of Cascading Optical Processes (Part IV)

Pathum Wathudura, Dongmao Zhang, Joshua McEachin
article en
3 citations

Abstract

Reproducibility and linearity are crucial benchmarks for any measurement technology. However, UV-vis and fluorescence spectral distortion and nonlinearity are prevalent, even in seemingly simple fluorescent solutions that comprise only one dissolved molecular fluorophore, without exogenous absorbing or scattering species. In this report, we introduce an analytical model for the quantification of fluorescence interference on UV-vis measurements and a conceptual model for mechanistically understanding the impacts of higher-order cascading optical processes on fluorescence measurements. The experimental UV-vis transmittance can be dominated by interfering fluorescence, even for fluorophore solutions with theoretical absorbance values far below the instrument's linear dynamic range (LDR). Absorption-inner-filter-effect (aIFE) correction drastically improves the fluorescence LDR. However, the efficacy of aIFE correction hinges on two competing factors that strongly depend on the fluorophore's optical properties: the degree of fluorescence interference in UV-vis and the significance of secondary or higher-order emission triggered by fluorophore absorption of emitted photons. Our research sheds light on the remarkable complexity of cascading optical processes that can occur even in the simplest fluorescent solutions. It emphasizes the necessity of critically evaluating optical spectroscopic measurements of fluorescent solutions to improve the reliability of analyzing and interpreting optical spectra. Moreover, it lays the groundwork for future development of methods capable of handling challenging samples that exceed the capabilities of the current tools.

Analytical ChemistryVol. 96(33)
Mississippi State University (US)
National Institute of General Medical Sciences, Division of Chemistry
Openalex Percentile: Top 30%
Protein Interaction Studies and Fluorescence Analysis
0.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Insights into Spectral Distortion and Nonlinearity in UV–Vis and Fluorescence Spectroscopy of Molecular Fluorophore Solutions: Effects of Cascading Optical Processes (Part IV) — Pathum Wathudura, Dongmao Zhang, et al. · Analytical Chemistry (2024) | TGRS Research Map | TGRS