Axial Compressive Performance of CFRP-Confined Corroded Reinforced Concrete Columns

In saline environments, it is difficult for reinforced concrete structures to meet normal durability requirements, which in turn affects the mechanical properties of the members. In this context, this paper proposes a reinforcement method that involves wrapping corroded reinforced concrete columns with CFRP (carbon fiber reinforced polymer) cloth. By conducting axial compression tests on four specimens, key mechanical performance indicators such as failure mode, ductility, and bearing capacity during the entire stress process of the specimens were analyzed, revealing the failure mechanism of CFRP-confined corroded reinforced concrete columns. A refined finite element model of CFRP-confined corroded reinforced concrete columns was established using ABAQUS software. The influence of key parameters such as the number of CFRP wrapping layers, longitudinal reinforcement corrosion rate, and axial compression ratio on the mechanical properties of the specimens was studied, and the influence of each parameter was determined. Furthermore, a formula for the axial compression bearing capacity of CFRP-confined corroded reinforced concrete columns was proposed. The results indicate that in the presence of corroded steel reinforcement, specimens confined with CFRP undergo substantial lateral constraints during the mid to late stages of loading. This approach effectively alleviates the transverse deformation of the concrete. The specimen demonstrated yield bearing capacities and peak loads of 1441 KN and 1934 KN, respectively, representing a 2.2-fold and 2.5-fold increase compared to the non-reinforced specimen. With the increase in the transverse strain of concrete, CFRP begins to play a restraint role, and a more obvious restraint role in the failure stage of members. It is recommended to apply 1–3 layers of CFRP wrapping for a longitudinal reinforcement corrosion rate of 5%, 3–5 layers for a rate of 10%, and 6–8 layers for an overall corrosion rate of 15%. This paper establishes a theoretical framework for investigating the performance characteristics of such columns and offers technical assistance for practical engineering purposes.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-08-05
DOI
https://doi.org/10.3390/buildings14082412
Citations
8
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
2.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial Compressive Performance of CFRP-Confined Corroded Reinforced Concrete Columns

Dan Xu, Hanghang Liu, Banglu Xi, Xun Zhang et al.
8 citations
Buildings
Structural Behavior of Reinforced Concrete
2.12
article

Axial Compressive Performance of CFRP-Confined Corroded Reinforced Concrete Columns

Dan Xu, Hanghang Liu, Banglu Xi, Xun Zhang, Yang Guo, Xiaochuan Chen
article en
8 citations

Abstract

In saline environments, it is difficult for reinforced concrete structures to meet normal durability requirements, which in turn affects the mechanical properties of the members. In this context, this paper proposes a reinforcement method that involves wrapping corroded reinforced concrete columns with CFRP (carbon fiber reinforced polymer) cloth. By conducting axial compression tests on four specimens, key mechanical performance indicators such as failure mode, ductility, and bearing capacity during the entire stress process of the specimens were analyzed, revealing the failure mechanism of CFRP-confined corroded reinforced concrete columns. A refined finite element model of CFRP-confined corroded reinforced concrete columns was established using ABAQUS software. The influence of key parameters such as the number of CFRP wrapping layers, longitudinal reinforcement corrosion rate, and axial compression ratio on the mechanical properties of the specimens was studied, and the influence of each parameter was determined. Furthermore, a formula for the axial compression bearing capacity of CFRP-confined corroded reinforced concrete columns was proposed. The results indicate that in the presence of corroded steel reinforcement, specimens confined with CFRP undergo substantial lateral constraints during the mid to late stages of loading. This approach effectively alleviates the transverse deformation of the concrete. The specimen demonstrated yield bearing capacities and peak loads of 1441 KN and 1934 KN, respectively, representing a 2.2-fold and 2.5-fold increase compared to the non-reinforced specimen. With the increase in the transverse strain of concrete, CFRP begins to play a restraint role, and a more obvious restraint role in the failure stage of members. It is recommended to apply 1–3 layers of CFRP wrapping for a longitudinal reinforcement corrosion rate of 5%, 3–5 layers for a rate of 10%, and 6–8 layers for an overall corrosion rate of 15%. This paper establishes a theoretical framework for investigating the performance characteristics of such columns and offers technical assistance for practical engineering purposes.

BuildingsVol. 14(8)
Hefei University of Technology (CN), Anhui Special Equipment Inspection Institute (CN), Anhui Institute of Architectural Research and Design (CN)
Sustainable cities and communities
Openalex Percentile: Top 14%
Structural Behavior of Reinforced Concrete
2.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.