Research on hot spot temperature inversion method of oil-immersed transformer based on multi-physical field coupling of magnetic-thermal-fluid

The hot spot temperature is an important factor affecting the operation state and insulation life of oil-immersed transformer. It is of great value to carry out multi-physical field coupling simulation research on magnetic-fluid-thermal field of oil-immersed transformer and accurately calculate and predict the hot spot temperature of transformer for transformer service life evaluation. In this paper, the oil immersed transformer is taken as the research object, and five characteristic parameters of the hysteresis model are obtained by using PSO algorithm according to the experimental magnetic characteristics data of the core material and the classical Jiles-Atherton (J-A) hysteresis model, A 3-D simulation model of magnetic-fluid-thermal field is established based on the electrical and structural parameters of the oil-immersed transformer. Combined with the magnetic characteristics of the core material, the thermal field and the surrounding fluid distribution of the transformer core and winding are obtained by two-way coupling method. On this basis, in order to accurately reflect the correlation between the hot spot temperature of the transformer winding and the temperature of the oil tank wall, the selection position of the characteristic temperature point of the transformer tank wall is determined by streamline analysis method, and the hot spot temperature of the oil-immersed transformer is retrieved by support vector machine method. The results show that the prediction accuracy of the hot spot temperature reaches 0.998, and the inversion method has a high enough accuracy. It provides theoretical basis and technical support for real-time monitoring of hot spot temperature in oil-immersed transformer windings.

Authors

Institutions

Publication Details

Journal
Thermal Science
Published
2024-08-05
DOI
https://doi.org/10.2298/tsci240330172g
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on hot spot temperature inversion method of oil-immersed transformer based on multi-physical field coupling of magnetic-thermal-fluid

ZhiXin Bai, Fating Yuan, NaiYue Zhang, Xuefeng Bai et al.
Thermal Science
Power Transformer Diagnostics and Insulation
article

Research on hot spot temperature inversion method of oil-immersed transformer based on multi-physical field coupling of magnetic-thermal-fluid

ZhiXin Bai, Fating Yuan, NaiYue Zhang, Xuefeng Bai, Lingyun Gu, WenPeng Gao, Xin Zhang, Yan Wu
article en

Abstract

The hot spot temperature is an important factor affecting the operation state and insulation life of oil-immersed transformer. It is of great value to carry out multi-physical field coupling simulation research on magnetic-fluid-thermal field of oil-immersed transformer and accurately calculate and predict the hot spot temperature of transformer for transformer service life evaluation. In this paper, the oil immersed transformer is taken as the research object, and five characteristic parameters of the hysteresis model are obtained by using PSO algorithm according to the experimental magnetic characteristics data of the core material and the classical Jiles-Atherton (J-A) hysteresis model, A 3-D simulation model of magnetic-fluid-thermal field is established based on the electrical and structural parameters of the oil-immersed transformer. Combined with the magnetic characteristics of the core material, the thermal field and the surrounding fluid distribution of the transformer core and winding are obtained by two-way coupling method. On this basis, in order to accurately reflect the correlation between the hot spot temperature of the transformer winding and the temperature of the oil tank wall, the selection position of the characteristic temperature point of the transformer tank wall is determined by streamline analysis method, and the hot spot temperature of the oil-immersed transformer is retrieved by support vector machine method. The results show that the prediction accuracy of the hot spot temperature reaches 0.998, and the inversion method has a high enough accuracy. It provides theoretical basis and technical support for real-time monitoring of hot spot temperature in oil-immersed transformer windings.

Thermal ScienceVol. 29(1 Part A)
North China Electric Power University (CN), China Three Gorges University (CN), China Energy Engineering Corporation (China) (CN), China Electric Power Research Institute
Responsible consumption and production
Openalex Percentile: Top 90%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies