Improving Access to Intracranial Volume Measurements for Clinical Use: Open-Source Method using Computed Tomography

Introduction: Three-dimensional measurements of intracranial volume (ICV) can guide clinical management of brain and skull disorders. However, widespread clinical access is limited by the scarcity of software methods for analyzing CT scans, which are more available than MRI images, and the inaccessibility of proprietary and expensive commercial software. The presented method can calculate ICV from CT scans, using an open-source software, 3D Slicer. Methods: The open-source workflow was optimized with a data-driven approach to find the optimal parameters for ICV accuracy. The accuracy of the open-source method was determined by comparing it to commercial and proprietary software with CT scans of pediatric hydrocephalic macrocephaly patients with craniosynostosis undergoing total vault reconstruction (N = 5 patients,15 scans). Results: An open-source pipeline that combines an initial semi-automatic segmentation of a coronal CT reconstruction with a fully automatic segmentation minimizes the ICV error. The open-source method shows excellent agreement with both the commercial and proprietary software methods (R 2 = 0.998 and 95% confidence interval of best-fit line slope: [0.986; 1.047], [0.985;1.066] respectively). The mean percent difference of ICV measurements of the open-source software from the commercial software was −0.56% [95% CI: −1.08%, −0.028%] and from the proprietary software was −0.07% [95% CI: −1.26%, 1.1%]. The mean percent difference of ICV measurements of the commercial software from the proprietary software was 0.36% [95% Confidence Interval: −0.61%, 1.32%]. Conclusions: This is the first study comparing an open-source method for measuring ICV with commercial and proprietary options. A high degree of fidelity was found, confirming this open-source method as a viable option for clinicians who are looking to incorporate ICV measurements into their practice.

Authors

Publication Details

Journal
FACE
Published
2024-08-05
DOI
https://doi.org/10.1177/27325016241268300
Citations
1
Primary Topic
Craniofacial Disorders and Treatments
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Access to Intracranial Volume Measurements for Clinical Use: Open-Source Method using Computed Tomography

Raymond Harshbarger, Sarah A. Frommer, Akhil Surapaneni
1 citations
FACE
Craniofacial Disorders and Treatments
0.55
article

Improving Access to Intracranial Volume Measurements for Clinical Use: Open-Source Method using Computed Tomography

Raymond Harshbarger, Sarah A. Frommer, Akhil Surapaneni
article en
1 citations

Abstract

Introduction: Three-dimensional measurements of intracranial volume (ICV) can guide clinical management of brain and skull disorders. However, widespread clinical access is limited by the scarcity of software methods for analyzing CT scans, which are more available than MRI images, and the inaccessibility of proprietary and expensive commercial software. The presented method can calculate ICV from CT scans, using an open-source software, 3D Slicer. Methods: The open-source workflow was optimized with a data-driven approach to find the optimal parameters for ICV accuracy. The accuracy of the open-source method was determined by comparing it to commercial and proprietary software with CT scans of pediatric hydrocephalic macrocephaly patients with craniosynostosis undergoing total vault reconstruction (N = 5 patients,15 scans). Results: An open-source pipeline that combines an initial semi-automatic segmentation of a coronal CT reconstruction with a fully automatic segmentation minimizes the ICV error. The open-source method shows excellent agreement with both the commercial and proprietary software methods (R 2 = 0.998 and 95% confidence interval of best-fit line slope: [0.986; 1.047], [0.985;1.066] respectively). The mean percent difference of ICV measurements of the open-source software from the commercial software was −0.56% [95% CI: −1.08%, −0.028%] and from the proprietary software was −0.07% [95% CI: −1.26%, 1.1%]. The mean percent difference of ICV measurements of the commercial software from the proprietary software was 0.36% [95% Confidence Interval: −0.61%, 1.32%]. Conclusions: This is the first study comparing an open-source method for measuring ICV with commercial and proprietary options. A high degree of fidelity was found, confirming this open-source method as a viable option for clinicians who are looking to incorporate ICV measurements into their practice.

FACEVol. 5(4)
Industry, innovation and infrastructure
Openalex Percentile: Top 27%
Craniofacial Disorders and Treatments
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving Access to Intracranial Volume Measurements for Clinical Use: Open-Source Method using Computed Tomography — Raymond Harshbarger, Sarah A. Frommer, et al. · FACE (2024) | TGRS Research Map | TGRS