Main Circuit's Parametric Optimal Design Counting Inconsistent Battery Parameters and Control of 35 kV Large-Capacity Transformer-Less BESS

A large quantity of battery cells are required by each phase of the 35 kV large-capacity transformer-less battery energy storage system (LCTL-BESS) based on cascaded H-bridge converter (CHBC) and the parameters of battery cells are inconsistent. The inconsistencies of battery parameters should be fully considered in main circuit parameter design to improve the system's adaptability to them, thus delaying the aging rate of battery and ensuring the safety and high efficiency utilization during the whole life cycle of battery. The cascaded number of power modules in per phase is the most important main circuit parameter of system and has a significant influence on system performance, which should be optimized by considering system efficiency and safety comprehensively. Since the system efficiency and safety evaluation model are closely related to inconsistent battery parameters, it is impossible to establish them under different number of power modules based on the detailed parameters of each battery cell. Therefore, a method to establish system efficiency and safety evaluation model based on the capacity distribution of the battery cells is proposed. The massive battery cell parameter identifications and data processing are avoided. Our proposed method provides theoretical guidance for the optimization design of main circuit for LCTL-BESS. Additionally, the power and energy balancing control of 35 kV LCTL-BESS are investigated, and a novel energy balancing control strategy among modules considering the DC link voltage and state of charge (SOC) are proposed under the nearest level modulation (NLM), which can promise both the balancing effect and AC side output performance. Finally, the validity of the proposed parameter design method and the control strategy are proved through off-line simulation model.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Energy Conversion
Published
2024-08-05
DOI
https://doi.org/10.1109/tec.2024.3438380
Citations
7
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
1.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Main Circuit's Parametric Optimal Design Counting Inconsistent Battery Parameters and Control of 35 kV Large-Capacity Transformer-Less BESS

Xu Cai, Chang Liu, Xianqiang Shi, Rui Li
7 citations
IEEE Transactions on Energy Conversion
Power Systems and Renewable Energy
1.19
article

Main Circuit's Parametric Optimal Design Counting Inconsistent Battery Parameters and Control of 35 kV Large-Capacity Transformer-Less BESS

Xu Cai, Chang Liu, Xianqiang Shi, Rui Li
article en
7 citations

Abstract

A large quantity of battery cells are required by each phase of the 35 kV large-capacity transformer-less battery energy storage system (LCTL-BESS) based on cascaded H-bridge converter (CHBC) and the parameters of battery cells are inconsistent. The inconsistencies of battery parameters should be fully considered in main circuit parameter design to improve the system's adaptability to them, thus delaying the aging rate of battery and ensuring the safety and high efficiency utilization during the whole life cycle of battery. The cascaded number of power modules in per phase is the most important main circuit parameter of system and has a significant influence on system performance, which should be optimized by considering system efficiency and safety comprehensively. Since the system efficiency and safety evaluation model are closely related to inconsistent battery parameters, it is impossible to establish them under different number of power modules based on the detailed parameters of each battery cell. Therefore, a method to establish system efficiency and safety evaluation model based on the capacity distribution of the battery cells is proposed. The massive battery cell parameter identifications and data processing are avoided. Our proposed method provides theoretical guidance for the optimization design of main circuit for LCTL-BESS. Additionally, the power and energy balancing control of 35 kV LCTL-BESS are investigated, and a novel energy balancing control strategy among modules considering the DC link voltage and state of charge (SOC) are proposed under the nearest level modulation (NLM), which can promise both the balancing effect and AC side output performance. Finally, the validity of the proposed parameter design method and the control strategy are proved through off-line simulation model.

IEEE Transactions on Energy ConversionVol. 40(1)
Shanghai Jiao Tong University (CN)
Affordable and clean energy
Openalex Percentile: Top 20%
Power Systems and Renewable Energy
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.