Influence and analysis of installation gap on mechanical test of servo actuator

Based on the study background of the fracture of the guide bearing of the actuator ball screw pair after the servo mechanism was subjected to mechanical vibration and impact environmental tests, a finite element model of the servo actuator was established, and product failure was analyzed using a combination of theoretical calculation and simulation analysis. Mechanism analysis used finite element analysis to calculate the response results of the actuator guide bearing under actual excitation response. The results showed that due to the installation gap at the connection between the actuator and the fixture, the mechanical response magnitude of the specimen during the test was too large and the bearing fracture occurred under the action of excessive radial load. By improving the test fixture, the test verification was completed.

Authors

Institutions

Publication Details

Published
2024-08-05
DOI
https://doi.org/10.1117/12.3039564
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence and analysis of installation gap on mechanical test of servo actuator

Lei Zhang, Enming Song, Lei Zhao, Zeng Wang et al.
Advanced Measurement and Metrology Techniques
article

Influence and analysis of installation gap on mechanical test of servo actuator

Lei Zhang, Enming Song, Lei Zhao, Zeng Wang, Zhe Pan, Shixin Kan
article en

Abstract

Based on the study background of the fracture of the guide bearing of the actuator ball screw pair after the servo mechanism was subjected to mechanical vibration and impact environmental tests, a finite element model of the servo actuator was established, and product failure was analyzed using a combination of theoretical calculation and simulation analysis. Mechanism analysis used finite element analysis to calculate the response results of the actuator guide bearing under actual excitation response. The results showed that due to the installation gap at the connection between the actuator and the fixture, the mechanical response magnitude of the specimen during the test was too large and the bearing fracture occurred under the action of excessive radial load. By improving the test fixture, the test verification was completed.

Beijing Jingshida Electromechanical Equipment Research Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 88%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.