Staged complex reconstruction of infected thoracic aortic endograft and adjacent spinal hardware using latissimus wrapped lateral aortic graft

Thoracic endovascular aortic repair (TEVAR) enables rapid and effective treatment of life-threatening aortic injuries. The occurrence of long-term complications from TEVAR and their management is ill-defined in young patients. This report describes a complex case of a 38-year-old male patient who underwent staged interventions for different acute pathologies instigated by blunt thoracic spinal trauma. The patient was initially treated with a TEVAR for aortic pseudoaneurysm in the setting of infected spinal hardware, which later resulted in an aortobronchial fistula and eroded spinal hardware. This report illustrates a successful multidisciplinary approach for definitive treatment with graft explant and aortic reconstruction.

Authors

Institutions

Publication Details

Journal
Journal of Vascular Surgery Cases and Innovative Techniques
Published
2024-08-05
DOI
https://doi.org/10.1016/j.jvscit.2024.101596
Primary Topic
Infectious Aortic and Vascular Conditions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Staged complex reconstruction of infected thoracic aortic endograft and adjacent spinal hardware using latissimus wrapped lateral aortic graft

John Bozinovski, David Xu, Joseph D. Bozzay, Kristine Orion et al.
Journal of Vascular Surgery Cases and Innovative Techniques
Infectious Aortic and Vascular Conditions
article

Staged complex reconstruction of infected thoracic aortic endograft and adjacent spinal hardware using latissimus wrapped lateral aortic graft

John Bozinovski, David Xu, Joseph D. Bozzay, Kristine Orion, Timur P. Sarac, Peter J. Kneuertz
article en

Abstract

Thoracic endovascular aortic repair (TEVAR) enables rapid and effective treatment of life-threatening aortic injuries. The occurrence of long-term complications from TEVAR and their management is ill-defined in young patients. This report describes a complex case of a 38-year-old male patient who underwent staged interventions for different acute pathologies instigated by blunt thoracic spinal trauma. The patient was initially treated with a TEVAR for aortic pseudoaneurysm in the setting of infected spinal hardware, which later resulted in an aortobronchial fistula and eroded spinal hardware. This report illustrates a successful multidisciplinary approach for definitive treatment with graft explant and aortic reconstruction.

Journal of Vascular Surgery Cases and Innovative TechniquesVol. 10(6)
The Ohio State University Wexner Medical Center (US)
Zero hunger
Openalex Percentile: Top 76%
Infectious Aortic and Vascular Conditions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.