Controlled labelling of tracer antibodies for time-resolved fluorescence-based immunoassays

Tracer antibodies, which are labelled with fluorescent or other type of reporter molecules, are widely employed in diagnostic immunoassays. Time-resolved fluorescence immunoassay (TRFIA), recognized as one of the most sensitive immunoassay techniques, utilizes tracers labelled with lanthanide ion (Ln) chelates. The conventional approach for conjugating isothiocyanate (ITC) Ln-chelates to antibodies involves random chemical targeting of the primary amino group of Lys residues, requiring typically overnight exposure to an elevated pH of 9-9.3 and leading to heterogeneity. Moreover, efforts to enhance the sensitivity of the assays by introducing a higher number of Ln-chelates per tracer antibody are associated with an elevated risk of targeting critical amino acid residues in the binding site, compromising the binding properties of the antibody. Herein, we report a method to precisely label recombinant antibodies with a defined number of Ln-chelates in a well-controlled manner by employing the SpyTag/SpyCatcher protein ligation technology. We demonstrate the functionality of the method with a full-length recombinant antibody (IgG) as well as an antibody fragment by producing site-specifically labelled antibodies for TRFIA for cardiac troponin I (cTnI) detection with a significant improvement in assay sensitivity compared to that with conventionally labelled tracer antibodies. Overall, our data clearly illustrates the benefits of the site-specific labelling strategy for generating high-performing tracer antibodies for TRF immunoassays.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-08-05
DOI
https://doi.org/10.1038/s41598-024-69294-7
Citations
2
Primary Topic
Monoclonal and Polyclonal Antibodies Research
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Controlled labelling of tracer antibodies for time-resolved fluorescence-based immunoassays

Saara Wittfooth, Rami Aalto, Anastasiia Kushnarova-Vakal, Urpo Lamminmäki et al.
2 citations
Scientific Reports
Monoclonal and Polyclonal Antibodies Research
0.81
article

Controlled labelling of tracer antibodies for time-resolved fluorescence-based immunoassays

Saara Wittfooth, Rami Aalto, Anastasiia Kushnarova-Vakal, Urpo Lamminmäki, Tuomas Huovinen
article en
2 citations

Abstract

Tracer antibodies, which are labelled with fluorescent or other type of reporter molecules, are widely employed in diagnostic immunoassays. Time-resolved fluorescence immunoassay (TRFIA), recognized as one of the most sensitive immunoassay techniques, utilizes tracers labelled with lanthanide ion (Ln) chelates. The conventional approach for conjugating isothiocyanate (ITC) Ln-chelates to antibodies involves random chemical targeting of the primary amino group of Lys residues, requiring typically overnight exposure to an elevated pH of 9-9.3 and leading to heterogeneity. Moreover, efforts to enhance the sensitivity of the assays by introducing a higher number of Ln-chelates per tracer antibody are associated with an elevated risk of targeting critical amino acid residues in the binding site, compromising the binding properties of the antibody. Herein, we report a method to precisely label recombinant antibodies with a defined number of Ln-chelates in a well-controlled manner by employing the SpyTag/SpyCatcher protein ligation technology. We demonstrate the functionality of the method with a full-length recombinant antibody (IgG) as well as an antibody fragment by producing site-specifically labelled antibodies for TRFIA for cardiac troponin I (cTnI) detection with a significant improvement in assay sensitivity compared to that with conventionally labelled tracer antibodies. Overall, our data clearly illustrates the benefits of the site-specific labelling strategy for generating high-performing tracer antibodies for TRF immunoassays.

Scientific ReportsVol. 14(1)
University of Turku (FI), Turku University Hospital (FI)
Academy of Finland, Turun Yliopisto, Business Finland, Turun Yliopistosäätiö, Turun yliopiston tutkijakoulu
Openalex Percentile: Top 27%
Monoclonal and Polyclonal Antibodies Research
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.