A self-adaptive model for sensing total phosphorus in natural water bodies using Fourier transform mid-infrared attenuated total reflectance spectroscopy

• FTIR-ATR could be applied in sensing total phosphorus in natural water body. • Sulfate was one of the main factors that interfered the sensing of total phosphorus. • Self-adaptive strategy provided a valuable resolution for sensing total phosphorus. As the most economically developed area in China, the environmental water quality of Guangdong-Hong Kong-Macao Greater Bay Area has received extensive attention, and the spatial variations of total phosphorus (TP) in the Greater Bay were significant, conventional laboratory analysis is difficult to meet the requirements of TP monitoring due to time and cost consuming, and Fourier transform infrared attenuated total reflectance spectroscopy (FTIR-ATR) technology, combined with the self-adaptive partial least squares (SA-PLS) model, was used to determine the TP concentration. The results showed that P-O vibrations were observed in the wavenumber range of 1200–900 cm −1 , and prediction models were established by using this range. For the conventional partial least squares (PLS) model, the R 2 , RMSE and RPD were 0.817, 0.022 mg L −1 and 2.335, respectively, while for the SA-PLS model the prediction was improved with the values of 0.965, 0.010 mg L −1 , 5.296, respectively, and the SA-PLS mode prediction was satisfied when the TP content in water was more than 0.05 mg L −1 . It was found that the TP determination was interfered by sulfate, when the sulfate content was < 100 mg L −1 , both SA-PLS and the conventional PLS model could be used for quantitative analysis of TP; when sulfate content was > 100 mg L −1 , PLS model could not be used while the SA-PLS model still achieved an excellent prediction. Therefore, FTIR-ATR combined with SA-PLS model can rapidly determine TP in water, providing an alternative strategy for monitoring TP in natural water bodies.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators Reports
Published
2024-08-05
DOI
https://doi.org/10.1016/j.snr.2024.100230
Citations
1
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.29

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A self-adaptive model for sensing total phosphorus in natural water bodies using Fourier transform mid-infrared attenuated total reflectance spectroscopy

Shuailin Zheng, Jianmin Zhou, Fei Ma
1 citations
Sensors and Actuators Reports
Water Quality Monitoring and Analysis
0.29
article

A self-adaptive model for sensing total phosphorus in natural water bodies using Fourier transform mid-infrared attenuated total reflectance spectroscopy

Shuailin Zheng, Jianmin Zhou, Fei Ma
article en
1 citations

Abstract

• FTIR-ATR could be applied in sensing total phosphorus in natural water body. • Sulfate was one of the main factors that interfered the sensing of total phosphorus. • Self-adaptive strategy provided a valuable resolution for sensing total phosphorus. As the most economically developed area in China, the environmental water quality of Guangdong-Hong Kong-Macao Greater Bay Area has received extensive attention, and the spatial variations of total phosphorus (TP) in the Greater Bay were significant, conventional laboratory analysis is difficult to meet the requirements of TP monitoring due to time and cost consuming, and Fourier transform infrared attenuated total reflectance spectroscopy (FTIR-ATR) technology, combined with the self-adaptive partial least squares (SA-PLS) model, was used to determine the TP concentration. The results showed that P-O vibrations were observed in the wavenumber range of 1200–900 cm −1 , and prediction models were established by using this range. For the conventional partial least squares (PLS) model, the R 2 , RMSE and RPD were 0.817, 0.022 mg L −1 and 2.335, respectively, while for the SA-PLS model the prediction was improved with the values of 0.965, 0.010 mg L −1 , 5.296, respectively, and the SA-PLS mode prediction was satisfied when the TP content in water was more than 0.05 mg L −1 . It was found that the TP determination was interfered by sulfate, when the sulfate content was < 100 mg L −1 , both SA-PLS and the conventional PLS model could be used for quantitative analysis of TP; when sulfate content was > 100 mg L −1 , PLS model could not be used while the SA-PLS model still achieved an excellent prediction. Therefore, FTIR-ATR combined with SA-PLS model can rapidly determine TP in water, providing an alternative strategy for monitoring TP in natural water bodies.

Sensors and Actuators ReportsVol. 8
University of Chinese Academy of Sciences (CN), Institute of Soil Science (CN)
National Natural Science Foundation of China, Chinese Academy of Sciences
Clean water and sanitation
Openalex Percentile: Top 40%
Water Quality Monitoring and Analysis
0.29
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.