Exploring Weak Magnetic Signal Characteristics of Pipeline Welds: Insights into Stress Non-Uniformity Effects

Weak magnetic detection technology can detect stress concentration areas in ferromagnetic materials. However, the stress non-uniform characteristics of pipeline welds lead to significant differences in stress distribution range and values between inner wall welds and outer wall welds. This discrepancy makes it crucial to further evaluate the impact of stress non-uniformity on magnetic signals. To study the magnetic signal characteristics under the influence of residual stress in weld seams, a magneto-mechanical analytical model was established based on the magnetic charge theory and the distribution characteristics of residual stress in the weld seam. The magneto-mechanical relationship and magnetic signal distribution characteristics at the inner and outer wall welds of the pipeline are calculated. Furthermore, the effects of different excitation intensities on the amplitude growth characteristics of magnetic signals are analyzed and compared. To verify the analysis model, weld detection experiments with different excitation intensities were designed. The results show that both the peak-to-valley values of the normal component and the peak values of the tangential component of the outer wall weld are lower than those of the inner wall weld. Conversely, the peak-to-valley width of the normal component and the peak width of the tangential component are greater than those of the inner wall weld. Additionally, the rate of increase in weak magnetic signal amplitude decreases in a first-order exponential relationship with increasing excitation intensity. The average decay rates of the normal and tangential component amplitude growth rates for the inner wall weld are 34.03% and 27.9%, respectively, while for the outer wall weld, they are 31.75% and 28.01%, respectively. This study contributes to the identification and quantitative assessment of weak magnetic signals in inner and outer wall welds.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-05
DOI
https://doi.org/10.3390/s24155074
Citations
3
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.64
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring Weak Magnetic Signal Characteristics of Pipeline Welds: Insights into Stress Non-Uniformity Effects

Lijian Yang, Xianfeng Fan
3 citations
Sensors
Non-Destructive Testing Techniques
0.64
article

Exploring Weak Magnetic Signal Characteristics of Pipeline Welds: Insights into Stress Non-Uniformity Effects

Lijian Yang, Xianfeng Fan
article en
3 citations

Abstract

Weak magnetic detection technology can detect stress concentration areas in ferromagnetic materials. However, the stress non-uniform characteristics of pipeline welds lead to significant differences in stress distribution range and values between inner wall welds and outer wall welds. This discrepancy makes it crucial to further evaluate the impact of stress non-uniformity on magnetic signals. To study the magnetic signal characteristics under the influence of residual stress in weld seams, a magneto-mechanical analytical model was established based on the magnetic charge theory and the distribution characteristics of residual stress in the weld seam. The magneto-mechanical relationship and magnetic signal distribution characteristics at the inner and outer wall welds of the pipeline are calculated. Furthermore, the effects of different excitation intensities on the amplitude growth characteristics of magnetic signals are analyzed and compared. To verify the analysis model, weld detection experiments with different excitation intensities were designed. The results show that both the peak-to-valley values of the normal component and the peak values of the tangential component of the outer wall weld are lower than those of the inner wall weld. Conversely, the peak-to-valley width of the normal component and the peak width of the tangential component are greater than those of the inner wall weld. Additionally, the rate of increase in weak magnetic signal amplitude decreases in a first-order exponential relationship with increasing excitation intensity. The average decay rates of the normal and tangential component amplitude growth rates for the inner wall weld are 34.03% and 27.9%, respectively, while for the outer wall weld, they are 31.75% and 28.01%, respectively. This study contributes to the identification and quantitative assessment of weak magnetic signals in inner and outer wall welds.

SensorsVol. 24(15)
Shenyang University of Technology (CN)
Life below water
Openalex Percentile: Top 36%
Non-Destructive Testing Techniques
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Exploring Weak Magnetic Signal Characteristics of Pipeline Welds: Insights into Stress Non-Uniformity Effects — Lijian Yang, Xianfeng Fan · Sensors (2024) | TGRS Research Map | TGRS