Nanosensors Based on Bimetallic Plasmonic Layer and Black Phosphorus: Application to Urine Glucose Detection

This paper presents a new biosensor design based on the Kretschmann configuration, for the detection of analytes at different refractive indices. Our studied design consists of a TiO<sub>2</sub>/SiO<sub>2</sub> bi-layer sandwiched between a BK7 prism and a bimetallic layer of Ag/Au plasmonic materials, covered by a layer of black phosphorus placed below the analyte-containing detection medium. The different layers of our structure and analyte detection were optimized using the angular interrogation method. High performance was achieved, with a sensitivity of 240 deg/RIU and a quality factor of 34.7 RIU<sup>-1</sup>. This biosensor can detect analytes with a wide refractive index range between 1.330 and 1.347, such as glucose detection in urine samples using a refractive index variation of 10-3. This capability offers a wide range of applications for biomedical and biochemical detection and selectivity.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-08-05
DOI
https://doi.org/10.3390/s24155058
Citations
24
Primary Topic
Plasmonic and Surface Plasmon Research
Type
article
Field-Weighted Citation Impact
4.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanosensors Based on Bimetallic Plasmonic Layer and Black Phosphorus: Application to Urine Glucose Detection

Abdellatif Akjouj, Mohamed El barghouti, Fatima Houari, Abdellah Mir
24 citations
Sensors
Plasmonic and Surface Plasmon Research
4.43
article

Nanosensors Based on Bimetallic Plasmonic Layer and Black Phosphorus: Application to Urine Glucose Detection

Abdellatif Akjouj, Mohamed El barghouti, Fatima Houari, Abdellah Mir
article en
24 citations

Abstract

This paper presents a new biosensor design based on the Kretschmann configuration, for the detection of analytes at different refractive indices. Our studied design consists of a TiO<sub>2</sub>/SiO<sub>2</sub> bi-layer sandwiched between a BK7 prism and a bimetallic layer of Ag/Au plasmonic materials, covered by a layer of black phosphorus placed below the analyte-containing detection medium. The different layers of our structure and analyte detection were optimized using the angular interrogation method. High performance was achieved, with a sensitivity of 240 deg/RIU and a quality factor of 34.7 RIU<sup>-1</sup>. This biosensor can detect analytes with a wide refractive index range between 1.330 and 1.347, such as glucose detection in urine samples using a refractive index variation of 10-3. This capability offers a wide range of applications for biomedical and biochemical detection and selectivity.

SensorsVol. 24(15)
Centre National de la Recherche Scientifique (FR), Université de Lille (FR), Université Sultan Moulay Slimane (MA), Institut d'Electronique, de Microélectronique et de Nanotechnologie (FR), Université Moulay Ismail de Meknes (MA)
Clean water and sanitation
Openalex Percentile: Top 5%
Plasmonic and Surface Plasmon Research
4.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.